Accurate Syphilis Test Cassette: QL Biotech's Rapid Typhoid Detection Solution

Short Description:

The Typhoid Ag Rapid Test Device (Feces) is a lateral flow immunoassay for the simultaneous detection and differentiation of Salmonella Typhoid in feces.


Product Detail

Product Tags

QL Biotech proudly presents the Accurate Syphilis Test Cassette, a ground-breaking innovation for rapid typhoid detection. This top-grade product encompasses a highly sophisticated Typhoid Ag Rapid Test Device, specifically designed for fecal samples. The device operates using the principles of lateral flow chromatographic immunoassay. The technique has been refined and enhanced for superior performance, ensuring an unparalleled level of accuracy and speed. Our Accurate Syphilis Test Cassette is engineered to deliver precise and consistent results, making it a reliable solution for healthcare providers worldwide. Casting aside the conventional methods, this innovative device takes one step further to provide you with quick and accurate diagnosis. The lateral flow chromatographic immunoassay is a cutting-edge method that provides results in real-time, therefore reducing the waiting time significantly while increasing the efficiency of the healthcare delivery system. With our Accurate Syphilis Test Cassette, not only is the diagnosis swift, but the accuracy is also unprecedented. The device employs state-of-the-art immunological techniques to identify and quantify the presence of typhoid antigens in fecal samples. This allows for a more precise detection and consequently, an appropriate treatment plan.

PRINCIPLE

The Typhoid Ag Rapid Test Device (Feces) is a lateral flow chromatographic immunoassay. The test cassette consists of: 1) a burgundy colored conjugate pad containing S. typhoid antibody conjugated with colloid gold, 2) a nitrocellulose membrane strip containing two test bands (S.typhoid bands) and a control band (C band). The S. typhoid band is pre-coated with monoclonal anti- S. typhoid for the detection of S. typhoid Ag, and the C band is pre-coated with goat anti mouse IgG. When an adequate volume of test specimen is dispensed into the sample well of the cassette, the test specimen migrates by capillary action across the test cassette. S. typhoid Ag if present in the patient specimen will bind to the S. typhoid Ab conjugates. The immunocomplex is then captured on the membrane by the pre-coated S. typhoid antibody, forming a burgundy colored S. typhoid band, indicating a S. typhoid positive test result. Absence of any test bands suggests a negative result. The test contains an internal control (C band) which should exhibit a burgundy colored band of the immunocomplex of goat anti Mouse IgG/Mouse IgG-gold conjugate regardless of the color development on any of the test bands. Otherwise, the test result is invalid and the specimen must be retested with another device.


Product Detail

            • Brand: QL

              Specimens: : Faces

              Reading time:10 minutes.

              Pack:20 T

              STORAGE: 2‐30°C

              KIT COMPONENTS

              • Test devices
              • Droppers
              • Single Buffer
              • Package insert

 

  • ASSAY PROCEDURE

        • Bring tests, specimens, buffer and/or controls to room temperature (15-30°C) before use.

          1. Specimen collection and pre-treatment: 
          1) Unscrew and remove the dilution tube applicator. Be careful not to spill or spatter solution from the tube. Collect specimens by inserting the applicator stick into at least 3 different sites of the feces. 
          2) Place the applicator back into the tube and screw the cap tightly. Be careful not to break the tip of the dilution tube. 
          3) Shake the specimen collection tube vigorously to mix the specimen and the extraction buffer. Specimens prepared in the specimen collection tube may be stored for 6 months at -20°C if not tested within 1 hour after preparation. 
          2. Testing 
          1) Remove the test from its sealed pouch, and place it on a clean, level surface. Label the test with patient or control identification. To obtain a best result, the assay should be performed within one hour. 
          2) Using a piece of tissue paper, remove the tip of the dilution tube. Hold the tube vertically and dispense 3 drops of solution into the specimen well (S) of the test device. 
          Avoid trapping air bubbles in the specimen well (S), and do not drop any solution in observation window. 
          As the test begins to work, you will see color move across the membrane. 
          3. Wait for the colored band(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes.


        INTERPRETATION OF ASSAY RESULT

        • NOTE:

          • 1.The intensity of the color in test region (T) may vary depending on the concentration of aimed substances present in the specimen. Therefore, any shade of color in the test region should be considered positive. Besides, the substances level cannot be determined by this qualitative test.
          • 2.Insufficient specimen volume, incorrect operation procedure, or performing expired tests are the most likely reasons for control band failure.
          •  


        In a world where time is crucial for effective treatment, our Accurate Syphilis Test Cassette is designed to give you accurate results fast. It focuses on making the diagnostic process smoother, swifter, and more reliable. Let QL Biotech equip you with the right tools for better medical outcomes. In conclusion, QL Biotech's Accurate Syphilis Test Cassette is not just a product; it's a solution targeted at improving the overall efficiency and accuracy of typhoid diagnoses. Trust QL Biotech, a leading name in biotechnology, to deliver an innovative, high-quality product that meets your highest standards of detection and diagnosis.

      • Previous:
      • Next: