The TB IgG/IgM Rapid Test Device (Whole Blood/Serum/Plasma) is a sandwich lateral flow chromatographic immunoassay for the qualitative detection of antibodies (IgG and IgM) anti-Mycobacterium Tuberculosis (M.TB) in human serum or plasma. It is intended to be used as a screening test and as an aid in the diagnosis of infection with M. TB. Any reactive specimen with the TB IgG/ IgM Rapid Test device must be confirmed with alternative testing method(s) and clinical findings.


Product Detail

Product Tags

QL Biotech is proud to introduce our Strep A IVDR Tuberculosis Rapid Test Device. This state-of-the-art tool offers a cutting-edge approach to TB diagnosis, utilizing the robust technology of lateral flow chromatographic immunoassay. This advanced technology operates on the principle of the Double Antigen Sandwitch Technique, bringing a new level of precision to the detection of TB antibodies. The Strep A IVDR Tuberculosis Rapid Test Device stands as a testament to QL Biotech's unwavering commitment to advancing health care solutions. Our pioneering technology, coupled with an unwavering focus on accuracy and speed, is designed to provide medical professionals and patients with the most efficient tools for diagnosis. As a testament to our innovative streak, the Strep A IVDR Tuberculosis Rapid Test Device ensures a seamless user experience, enabling swift and accurate TB diagnosis. The device's functional design rooted in its thorough understanding of the clinical landscape, positions it as a reliable tool for medical professionals and institutions.

PRINCIPLE

The TB Antibody Rapid Test device is a lateral flow chromatographic immunoassay based on the principle of the double antigen–sandwich technique. The test cassette consists of: 1) a burgundy colored conjugate pad containing M.TB antigens conjugated with colloid gold (M.TB conjugates)and rabbit IgG‐gold conjugates, 2) a nitrocellulose membrane strip containing a test band (T band) and a control band (C band). The T band is pre‐coated with non‐conjugated M.TB antigens, and the C band is pre‐coated with goat anti‐rabbit IgG. When an adequate volume of test specimen is dispensed into the sample well of the cassette, the specimen migrates by capillary action across the cassette. The antibodies: either the IgG, the IgM to M. TB if present in the specimen will bind to the M.TB conjugates. The immunocomplex is then captured on the membrane by the pre‐coated M.TB antigens, forming a burgundy colored T band, indicating a M.TB Ab positive test result. Absence of the T band suggests a negative result. The test contains an internal control (C band) which should exhibit a burgundy colored band of the immunocomplex of goat anti‐rabbit IgG/rabbit IgG‐gold conjugate regardless the presence of any antibodies to M.TB. Otherwise, the test result is invalid and the specimen must be retested with another device.


Product Detail

          • Brand: QL

            Specimens: :Plasma/ Serum/ Whole Blood

            Reading time:1 minutes.

            Pack:25 T

            STORAGE: 2‐30°C

            KIT COMPONENTS

            • Test devices
            • Droppers
            • Buffer
            • Package insert

 

  • TEST PRINCIPLE

        • The TB IgG/IgM Rapid Test Device (Whole Blood/Serum/Plasma) is a lateral flow chromatographic immunoassay based on the principle of the double antigen–sandwich technique. The test cassette consists of: 1) a burgundy colored conjugate pad containing M.TB antigens conjugated with colloid gold (M.TB conjugates) and rabbit IgG‐gold conjugates, 2) a nitrocellulose membrane strip containing a test band (T band) and a control band (C band). The T band is pre‐coated with non‐conjugated M.TB antigens, and the C band is pre‐coated with goat anti‐rabbit IgG.

          When an adequate volume of test specimen is dispensed into the sample well of the cassette, the specimen migrates by capillary action across the cassette. The antibodies: either the IgG, the IgM to M. TB if present in the specimen will bind to the M.TB conjugates. The immunocomplex is then captured on the membrane by the pre‐coated M.TB antigens, forming a burgundy colored T band, indicating a M.TB Ab positive test result.

          Absence of the T band suggests a negative result. The test contains an internal control (C band) which should exhibit a burgundy colored band of the immunocomplex of goat anti‐rabbit IgG/rabbit IgG‐gold conjugate regardless the presence of any antibodies to M.TB. Otherwise, the test result is invalid and the specimen must be retested with another device.


        ASSAY PROCEDURE

        1. Bring the specimen and test components to room temperature. Place the test device  on a clean, flat surface. 
        2. Be sure to label the device with specimen’s ID number. 
        3. Fill the plastic dropper with the specimen. Holding the dropper vertically, dispense 2  drops (about 80 µL) of specimen into the sample well making sure that there are no  air bubbles. Then add 1 drop of buffer into the sample well. Set up timer. 
        4. Results can be read in 10 minutes. Positive results can be visible in as short as 1  minute. Don’t read result after 10 minutes. To avoid confusion, discard the test  device after interpreting the result.

        •  
        • INTERPRETATION OF ASSAY RESULT



          IgG Positive:* The colored line in the control line region (C) appears and a colored line appears in test line region IgG. The result is positive for Tuberculosis specific-IgG antibodies and is indicative of secondary Tuberculosis infection.

          IgM Positive:* The colored line in the control line region (C) appears and a colored line appears in test line region IgM. The result is positive for Tuberculosis specific-IgM and is probably indicative of primary Tuberculosis infection.

          IgG and IgM Positive:* The colored line in the control line region (C) appears and two colored lines should appear in test line regions IgG and IgM. The color intensities of the lines do not have to match. The result is positive for IgG & IgM antibodies and is indicative of secondary Tuberculosis infection.

          *NOTE: The intensity of the color in the test line region(s) will vary depending on the concentration of Tuberculosis antibodies in the specimen. Therefore, any shade of color in the test line region(s) should be considered positive.

          NEGATIVE RESULT:

          The colored line in the control line region (C) appears. No line appears in test line regions IgG or IgM.

          INVALID RESULT:

          Control line (C) falls to appear. Insufficient buffer volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the procedure with a new test device. If the problem persists, discontinue using the test kit immediately and contact your local distributor.
           



        In the fight against Tuberculosis, speed and accuracy are undeniably critical. The Strep A IVDR Tuberculosis Rapid Test Device seeks to bolster these aspects, offering users an unmatched diagnostic tool that is built to cater to the needs of a dynamic healthcare landscape. At QL Biotech, we continue to strive towards transforming diagnostic procedures, ensuring that every solution we offer contributes to enhancing global health outcomes. Experience the revolution in TB diagnosis with QL Biotech's Strep A IVDR Tuberculosis Rapid Test Device. A blend of modern technology and a rich understanding of the field, it exemplifies our dedication to providing robust and comprehensive healthcare solutions. Join us in our journey towards a healthier world, one accurate diagnosis at a time.