Advanced TB Igg/Igm Combo Rapid Test Device for HBsAg Detection

Short Description:

The HBsAg Rapid Test Strip/DeviceWhole Blood/Serum/Plasma)is a rapid visual immunoassay for the qualitative presumptive detection of HBsAg in human whole blood, serum, or plasma specimens. This kit is intended to be used as an aid in the diagnosis of HBV infection.


Product Detail

Product Tags

QL Biotech proudly presents a state-of-the-art and scientifically advanced product, the TB Igg/Igm Combo Rapid Test Device. Specifically designed for the detection of HBsAg (Hepatitis B surface antigen), our Rapid Test Device provides medical professionals with fast, accurate and reliable results. Our Rapid Test Device employs the principle of visual interpretation of color development in the test strip. As antigens in a patient's serum or plasma sample are introduced to the test strip, the presence of HBsAg triggers a color change, indicating a positive test result. This method allows for a convenient and straightforward interpretation, minimizing potential errors and ambiguities. The TB Igg/Igm Combo Rapid Test cuts down waiting time and accelerates treatment initiation by offering rapid results. In an era where speed is of essence, our rapid testing device becomes a crucial tool for healthcare providers, enabling them to swiftly diagnose and begin necessary treatment plans. With a focus on ensuring the highest level of accuracy, QL Biotech's TB Igg/Igm Combo Rapid Test Device undergoes rigorous quality control procedures. Our commitment to excellence ensures that our tests provide dependable outcomes, fostering trust and confidence among healthcare providers and patients alike. We, at QL Biotech, understand the importance of early detection in the effective management of Hepatitis B. Hence, we have designed our TB Igg/Igm Combo Rapid Test Device to be easy-to-use, quick and accurate - a crucial companion for medical professionals in the fight against this global health issue.

PRINCIPLE

The HBsAg Rapid Test Device (Serum/Plasma) has been designed to detect the HBsAg through visual interpretation of color development in the strip. The membrane was immobilized with anti‐ HBsAg antibodies on the test region. During the test, the specimen is allowed to react with colored anti‐HBsAg antibodies colloidal gold conjugates, which were precoated on the sample pad of the test. The mixture then moves on the membrane by a capillary action, and interact with reagents on the membrane. If there were enough HBsAg in specimens, a colored band will from at the test region of the membrane. Presence of this colored band indicates a positive result, while its

absence indicates a negative result. Appearance of a colored band at the control region serves as a procedural control. This indicates that proper volume of specimen has been added and membrane wicking has occurred.


Product Detail

Brand: QL

Specimens: : Serum/Plasma

Reading timeDevice15 minutes./ Strip 10 minutes.

Pack:25 T

STORAGE: 2‐30°C

KIT COMPONENTS

1

Individually packed test devices

Disposable pipettes

Buffer

Package insert

2

Individually packed test strips 

Disposable pipettes

Package insert

 

PROCEDURE

    • HBsAg Rapid Test Strip
      Bring tests, specimens and/or controls to room temperature (15‐30°C) before use. 
      1. Transfer 3 drop of specimen to a specimen reaction tube with a disposable pipette provided in the kit.
      2. Remove the test from its sealed pouch and use it as soon as possible. To obtain a best result, the assay should be performed within one hour. 
      3. Hold the strip at the handle with the product name imprints. Do not touch the membrane part of the strip to avoid contamination. 
      4. Dip the test strip vertically in the specimen for at least 10‐15 seconds. Do not pass the maximum line (MAX) on the test strip when immersing the strip. 
      As the test begins to work, you will see color move across the membrane. 
      5. Take the strip out of the specimen afterwards and place it on a non‐absorbents flat surface. 
      Start the timer and wait for the colored line(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes.
      HBsAg Rapid Test Device
      Bring tests, specimens and/or controls to room temperature (15‐30°C) before use. 
      1. Remove the test from its sealed pouch, and place it on a clean, level surface. Label the test with patient or control identification. To obtain a best result, the assay should be performed 
      within one hour
      Transfer 2 drops of serum/plasma to the specimen well of the device with a disposable pipette provided in the kit, then add 1 drop of buffer and start the timer. 
      Avoid trapping air bubbles in the specimen well (S), and do not drop any solution in observation window. 
      As the test begins to work, you will see color move across the membrane. 
      2. Wait for the colored band(s) to appear. The result should be read at 15 minutes. Do not interpret the result after 20 minutes.

    INTERPRETATION OF RESULTS






    As providers of innovative biotech solutions, QL Biotech continuously strives to improve and update our product offerings. We ensure our TB Igg/Igm Combo Rapid Test Device stays at the forefront of rapid testing technology, providing optimal solutions for the early detection and management of Hepatitis B. Experience the next level of healthcare solutions with QL Biotech's TB Igg/Igm Combo Rapid Test - Quick. Reliable. Accurate.