Fast & Reliable Adeno Test: RSV Antigen Detection Kit

Short Description:

The RSV Ag Rapid Test Strip (Swab) is a rapid visual immunoassay for the qualitative, presumptive detection of Respiratory syncytial virus (RSV) antigens form Nasal swabs and nasopharyngeal swab specimens. The test is intended for use as an aid in the rapid differential diagnosis of acute Respiratory syncytial virus infection.


Product Detail

Product Tags

In the ever-evolving field of biotechnology, rapid and accurate diagnostic tools are essential for the management and control of infectious diseases. QL Biotech is proud to introduce our latest innovation: the Respiratory Syncytial Virus (RSV) Antigen Rapid Test Device, an advanced solution designed for the swift detection of RSV, a common respiratory virus that poses significant risks, particularly to infants, the elderly, and immunocompromised individuals. This cutting-edge Adeno Test seamlessly combines efficiency with precision, offering a vital tool in the fight against respiratory infections.

PRINCIPLE

The RSV Ag Rapid Test device (Swab) detects RSV antigens through visual interpretation of color development on the strip. RSV antibodies are immobilized on the test region of the membrane respectively. During testing, the extracted specimen reacts with anti- RSV antibodies conjugated to colored particles and precoated onto the sample pad of the test. The mixture then migrates through the membrane by capillary action and interacts with reagents on the membrane. If there is sufficient RSV antigens in the specimen, colored band will form at the according test region of the membrane. The presence of a colored band in the test region indicates a positive result for the particular viral antigens, while its absence indicates a negative result. The appearance of a colored band at the control region serves as a procedural control, indicating that the proper volume of specimen has been added and membrane wicking has occurred.


Product Detail

    • Brand: QL

      Specimens: : Nasopharyngeal swabs/ Nasal swab

      Reading time:10 minutes.

      Pack:20 T

      STORAGE: 2‐30°C

      KIT COMPONENTS(Device)

      Individually packed Test Devices

      Extraction solution

      Extraction tubes

      Sterile nasal swabs

      Package insert

 

PROCEDURE

    • Bring tests, specimens, and/or controls to room temperature (15-30°C) before use. 
      1. Remove the test from its sealed pouch, and place it on a clean, level surface. Label the Strip with patient or control identification. For best results, the assay should be performed within one hour. 
      2. Gently mix Extraction reagent solution. 
      For bottle buffer: Add 5 drops (about 200ul) of the Extraction Solution into the Extraction tube. 
      For single buffer: transfer all buffer (about 200ul) into the extraction tube. 
      3. Place the patient swab specimen into the Extraction Tube. Roll the swab at least 10 times while pressing the swab against the bottom and side of the Extraction Tube. Roll the swab head against the inside of the Extraction Tube as you remove it. Try to release as much liquid as possible. Dispose of the used swab in accordance with your biohazard waste disposal protocol. 
      4. Put the strip into the extraction test tube and then start the timer. 
      5. As the test begins to work, color will migrate across the membrane. Wait for the colored band(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes.

    RESULTS


    • POSITIVE RESULT:
    • A colored band appears in the control band region (C) and another colored band appears in the T band region
    • NEGATIVE RESULT:
    • One colored band appears in the control band region (C). No band appears in the test band region (T)
    • INVALID RESULT:
    • Control band fails to appear. Results from any test which has not produced a control band at the specified reading time must be discarded. Please review the procedure and repeat with a new test. If the problem persists, discontinue using the kit immediately and contact your local distributor
    • NOTE:
    • 1.The intensity of the color in test region (T) may vary depending on the concentration of aimed substances present in the specimen. Therefore, any shade of color in the test region should be considered positive. Besides, the substances level can’t be determined by this qualitative test.
    • 2.Insufficient specimen volume, incorrect operation procedure, or performing expired tests are the most likely reasons for control band failure.

     



    The principle behind our RSV Antigen Rapid Test Device lies in its sophisticated design, which employs a direct antigen detection method. Utilizing a simple swab sample, the test identifies the presence of RSV antigens through a colorimetric assay, where results are visually interpreted. This method not only ensures high specificity and sensitivity but also enables rapid diagnosis, with results available in a matter of minutes. The ease of use and quick turnaround time make the RSV Ag Rapid Test an indispensable asset for healthcare providers, enabling immediate decision-making and early intervention. Our commitment at QL Biotech extends beyond providing top-tier diagnostic tools. We understand the importance of reliability and accuracy in healthcare settings, which is why our RSV Antigen Rapid Test Device is rigorously tested to meet the highest standards of quality. Designed for use in a variety of settings, from hospitals and clinics to fieldwork and home care, this Adeno Test is a versatile tool in the management of respiratory infections. By offering a rapid, reliable, and easy-to-use diagnostic solution, QL Biotech aims to contribute to the global effort in controlling the spread of RSV and ultimately protecting public health.

  • Previous:
  • Next: