HBsAg Rapid Test Strip - Quick & Accurate Results

Short Description:

The HBsAg Rapid Test Strip/Device is a rapid visual immunoassay for the qualitative presumptive detection of HBsAg in human whole blood, serum, or plasma specimens. This kit is intended to be used as an aid in the diagnosis of HBV infection. 


Product Detail

Product Tags

In the rapidly evolving landscape of medical diagnostics, timely and accurate detection of infectious diseases is paramount. QL Biotech introduces the pinnacle of innovation with the HBsAg Rapid Test Device/Strip, a groundbreaking solution designed to significantly enhance the efficacy and reliability of Hepatitis B surface antigen (HBsAg) detection. This advanced diagnostic tool represents a monumental leap in healthcare technology, meticulously engineered for use with whole blood, serum, or plasma samples.

PRINCIPLE

The HBsAg Rapid Test Device (Whole Blood/Serum/Plasma) has been designed to detect the HBsAg through visual interpretation of color development in the strip. The membrane was immobilized with anti‐ HBsAg antibodies on the test region. During the test, the specimen is allowed to react with colored anti‐HBsAg antibodies colloidal gold conjugates, which were precoated on the sample pad of the test. The mixture then moves on the membrane by a capillary action, and interact with reagents on the membrane. If there were enough HBsAg in specimens, a colored band will from at the test region of the membrane. Presence of this colored band indicates a positive result, while its absence indicates a negative result. Appearance of a colored band at the control region serves as a procedural control. This indicates that proper volume of specimen has been added and membrane wicking has occurred.


Product Detail

Brand: QL

Specimens: : Whole Blood/Serum/Plasma

Reading time:20 minutes.

Pack:25 T

STORAGE: 2‐30°C

KIT COMPONENTS

Individually packed test devices

Disposable pipettes

Buffer

Package insert

 

PROCEDURE

    • HBsAg Rapid Test Strip(Whole Blood/Serum/Plasma)
      Bring tests, specimens and/or controls to room temperature (15‐30°C) before use. 
      1. Remove the test strip from the sealed pouch and use it as soon as possible. Best results will be obtained if the assay is performed within one hour.
      2. For Serum or Plasma specimens: Hold the dropper vertically and transfer 2 drops of serum or plasma (approximately 50L) onto the Specimen Pad of the test strip, then start the timer. 
      For Venipuncture Whole Blood specimens: Hold the dropper vertically and transfer 2 drops of whole blood (approximately 50L) onto the Specimen Pad of the test strip, then add 2
      drops of buffer (approximately 80L) and start the timer. 
      For Fingerstick Whole Blood specimens:
      Fill the capillary tube and transfer approximately 50L (or 2 drops) of fingerstick whole blood specimen onto the Specimen Pad of the test strip, then add 2 drops of buffer (approximately 80 L) and start the timer. 
      3. Wait for the colored band(s) to appear. The result should be read at 15 minutes. Do not interpret the result after 20 minutes.
      HBsAg Rapid Test Device(Whole Blood/Serum/Plasma)
      Bring tests, specimens and/or controls to room temperature (15‐30°C) before use. 
      1. Remove the test from its sealed pouch, and place it on a clean, level surface. Label the test with patient or control identification. To obtain a best result, the assay should be performed 
      within one hour. 
      Transfer 2 drops of serum/plasma to the specimen well of the device with a disposable pipette provided in the kit and then start the timer.
      OR
      Transfer 2 drop of whole blood to the specimen well of the device with a disposable pipette provided in the kit, then add 1 drop of buffer and start the timer. 
      OR
      Transfer 2 drop of whole blood to the specimen well of the device with a disposable pipette provided in the kit, then add 1 drop of buffer and start the timer. 
      OR
      Transfer 2 drop of whole blood to the specimen well of the device with a disposable pipette provided in the kit, then add 1 drop of buffer and start the timer.
      OR
      Allow 2 hanging drop of fingerstick whole blood specimen to fall into the center of the specimen well (S) on the device, then add 1 drop of buffer and start the timer.
      Avoid trapping air bubbles in the specimen well (S), and do not drop any solution in observation window. 
      As the test begins to work, you will see color move across the membrane. 
      2. Wait for the colored band(s) to appear. The result should be read at 15 minutes. Do not interpret the result after 20 minutes.

    INTERPRETATION OF RESULTS






    At the heart of the HBsAg Rapid Test Device/Strip lies a sophisticated mechanism that seamlessly integrates cutting-edge scientific principles to deliver swift and precise results through color development. This visual interpretation of results not only simplifies the detection process but also ensures clarity and confidence in diagnosis. Tailored for both clinical and at-home settings, our test strips serve as a beacon of hope, promoting early detection and intervention which are critical in managing and controlling the spread of the Hepatitis B virus (HBV). Our commitment to excellence is reflected in every aspect of the HBsAg Rapid Test Device/Strip, from its conception to execution. By harnessing the power of innovative technology, we provide a test that is not only highly sensitive and specific but also user-friendly. It's designed to be accessible to a wide range of users, from medical professionals in clinical settings to individuals seeking private testing in the comfort of their homes. Embrace the future of Hepatitis B testing with QL Biotech's HBsAg Rapid Test Device/Strip, your reliable partner in the quest for health and wellness.

  • Previous: