High Efficacy Disposable Syphilis Rapid Test Device by QL Biotech

Short Description:

The Strep A Rapid Test Device/Strip is a rapid chromatographic immunoassay for the qualitative detection of Strep A antigen from throat swab specimens to aid in the diagnosis of Group A Streptococcal infection.


Product Detail

Product Tags

Introducing QL Biotech's revolutionary Disposable Syphilis Rapid Test Device - an advanced solution for swift, reliable, and accurate detection of Syphilis. Leveraging the qualitative, lateral flow immunoassay technique, this test device is a game-changer in rapid diagnostic testing. The device operates on the principle of detecting the presence of the Strep A carbohydrate antigen, commonly found in a throat swab of Syphilis-infected individuals. Our Disposable Syphilis Rapid Test Device is designed to simplify and expedite the testing process, thus reducing stress and uncertainty. With its easy-to-read results, the user can have clear, accurate information about their health status conveniently and discretely.

PRINCIPLE

The Strep A Rapid Test Device/strip is a qualitative, lateral flow immunoassay for the detection of Strep A carbohydrate antigen in a throat swab. In this test, antibody specific to Strep A carbohydrate antigen is coated on the test line region of the test. During testing, the extracted throat swab specimen reacts with an antibody to Strep A that is coated onto particles. The mixture migrates up the membrane to react with the antibody to Strep A on the membrane and generate a color line in the test line region. The presence of this color line in the test line region indicates a positive result, while its absence indicates a negative result. To serve as a procedural control, a colored line will always appear in the control line region, indicating that proper volume of specimen has been added and membrane wicking has occurred.


Product Detail

    • Brand:QL

      Specimens: : Swab

      Reading time:5 minutes.

      Pack:20 T

      STORAGE: 2‐30°C

      KIT COMPONENTS(Device)

      •  •Test devices                            •Sterile swabs
      •  •Workstation                         • Strep A Reagent A (1M Sodium Nitrite )
      •  •Strep A Reagent B (0.4M Acetic Acid)      • Test tubes
      •  •Dropper tips                          • Package insert

       

      KIT COMPONENTS(strip)

      •  •Test strips                           • Sterile swabs
      •  •Workstation                          • Strep A Reagent A (1M Sodium Nitrite )
      •  •Strep A Reagent B (0.4M Acetic Acid)   • Test tubes
      •  •Package insert

 

PROCEDURE

    • Allow the test device, reagents, throat swab specimen, and/or controls to reach room temperature (15-30°C) prior to testing. 
      1. Remove the test device from the sealed foil pouch and use it as soon as possible. 
      Best results will be obtained if the test is performed immediately after opening the foil pouch. 
      2. Hold the Reagent A bottle vertically and add 4 full drops (approximately 240 µL) of Reagent A to an extraction test tube. Reagent A is red in color. Hold the 
      Reagent B bottle vertically and add 4 full drops (approximately 160 µL) to the tube. Reagent B is colorless. Mix the solution by gently swirling the extraction test tube. The addition of Reagent B to Reagent A changes the color of the solution from red to yellow. 
      3. Immediately add the throat swab to the extraction test tube of yellow solution. Agitate the swab 10 times in the tube. Leave the swab in the tube for 1 minute. Then press the swab against the side of the tube and squeeze the bottom of the tube as the swab is withdrawn. Discard the swab. 
      4. Fit the dropper tip on top of the extraction test tube. Place the test device on a clean and level surface. Add 3 full drops of solution (approx. 100 µL) to the specimen well (S) and then start the timer. 
      5. Wait for the colored line(s) to appear. Read the result at 5 minutes. Do not read the result after 10 minutes.

    INTERPRETATION OF RESULTS


    • NOTE:
    • The intensity of the color in test region (T) may vary depending on the concentration of aimed substances present in the specimen. Therefore, any shade of color in the test region should be considered positive. Besides, the substances level can not be determined by this qualitative test.
    • Insufficient specimen volume, incorrect operation procedure, or performing expired tests are the most likely reasons for control band failure.

     



    Our Disposable Syphilis Rapid Test Device is a crucial advancement in the field of medical testing. It represents a significant leap forward in providing rapid, dependable detection of Syphilis, ensuring the accessibility of essential health information. Trust in QL Biotech's proven expertise and commitment to quality in medical solutions to deliver reliable, rapid results when it matters most. Choose the Disposable Syphilis Rapid Test Device for a modern, user-friendly, and efficient approach to Syphilis detection. Make no compromise on your health - choose quick detection, trust in QL Biotech.