The TB Antibody Rapid Test device is a sandwich lateral flow chromatographic immunoassay for the qualitative detection of antibodies (IgG and IgM) anti‐Mycobacterium Tuberculosis (M.TB) in human serum or plasma. It is intended to be used as a screening test and as an aid in the diagnosis of infection with M. TB. Any reactive specimen with the TB Antibody Rapid Test device must be confirmed with alternative testing method(s) and clinical findings.


Product Detail

Product Tags

Introducing the Tuberculosis Antibody Rapid Test Device, a revolutionary Strep A self-testing tool developed by QL Biotech. This device is not just a standard testing tool; it symbolizes a significant breakthrough in the medical field. Using the principle of the double antigen-sandwich technique, it's a lateral flow chromatographic immunoassay device that efficiently detects Strep A and provides accurate results in no time. The device utilizes a simple, user-friendly design that makes Strep A self-testing accessible and convenient for all users. Its design embodies an epitome of cutting-edge innovation from QL Biotech, a market leader in biotech solutions. Our company is dedicated to progressing the world of medicine and enhancing user experiences. By creating reliable, quick, and easy-to-use tools like the Tuberculosis Antibody Rapid Test Device, we're revolutionizing Strep A self-testing and making it more attainable for individuals around the globe. Strep A self-testing is an essential tool in managing and preventing the spread of conditions such as strep throat. Our Tuberculosis Antibody Rapid Test Device ensures a high degree of accuracy, providing you with the reassurance and knowledge you need to take the necessary steps regarding your health. This device is a testament to QL Biotech's commitment to delivering innovative, state-of-the-art testing solutions. As we continue to break new ground in our field, we're proud to bring you the Tuberculosis Antibody Rapid Test Device, designed for effective Strep A self-testing. Whether it's for personal use or professional, this device promises reliability, accuracy, convenience, and peace of mind. Explore the transformative world of Strep A self-testing with QL Biotech's Tuberculosis Antibody Rapid Test Device today.

PRINCIPLE

The TB Antibody Rapid Test device is a lateral flow chromatographic immunoassay based on the principle of the double antigen–sandwich technique. The test cassette consists of: 1) a burgundy colored conjugate pad containing M.TB antigens conjugated with colloid gold (M.TB conjugates)and rabbit IgG‐gold conjugates, 2) a nitrocellulose membrane strip containing a test band (T band) and a control band (C band). The T band is pre‐coated with non‐conjugated M.TB antigens, and the C band is pre‐coated with goat anti‐rabbit IgG. When an adequate volume of test specimen is dispensed into the sample well of the cassette, the specimen migrates by capillary action across the cassette. The antibodies: either the IgG, the IgM to M. TB if present in the specimen will bind to the M.TB conjugates. The immunocomplex is then captured on the membrane by the pre‐coated M.TB antigens, forming a burgundy colored T band, indicating a M.TB Ab positive test result. Absence of the T band suggests a negative result. The test contains an internal control (C band) which should exhibit a burgundy colored band of the immunocomplex of goat anti‐rabbit IgG/rabbit IgG‐gold conjugate regardless the presence of any antibodies to M.TB. Otherwise, the test result is invalid and the specimen must be retested with another device.


Product Detail

        • Brand: QL

          Specimens: : Serum/Plasma

          Reading time:1 minutes.

          Pack:25 T

          STORAGE: 2‐30°C

          KIT COMPONENTS

          • Test devices
          • Droppers
          • Buffer
          • Package insert

 

  • ASSAY PROCEDURE

        • 1. Bring the specimen and test components to room temperature. Place the test device  on a clean, flat surface. 
          2. Be sure to label the device with specimen’s ID number. 
          3. Fill the plastic dropper with the specimen. Holding the dropper vertically, dispense 2  drops (about 80 µL) of specimen into the sample well making sure that there are no  air bubbles. Then add 1 drop of buffer into the sample well. Set up timer. 
          4. Results can be read in 10 minutes. Positive results can be visible in as short as 1  minute. Don’t read result after 10 minutes. To avoid confusion, discard the test  device after interpreting the result.


        INTERPRETATION OF RESULTS


          •  


        (QR Code: Scan here to explore more about this unique product) Dive deep into Strep A self-testing and explore how it can change your life for the better with our Tuberculosis Antibody Rapid Test Device. Empower yourself and take control of your health with QL Biotech.