HSV IgM Rapid Test Kit - Quick & Reliable Diagnosis

Short Description:

The S. typhoid/S. Para typhi Ag Rapid Test Device (Feces) is a lateral flow immunoassay for the simultaneous detection and differentiation of Salmonella typhi and Salmonella P. Typhoid in feces.


Product Detail

Product Tags

In the realm of medical diagnostics, speed and accuracy are paramount. At QL Biotech, we have dedicated our research and development efforts to meet these critical needs with our innovative HSV IgM Rapid Test Device. This cutting-edge test provides healthcare professionals and patients alike with a quick, reliable means of detecting the presence of Herpes Simplex Virus (HSV) IgM antibodies, marking an important step in early diagnosis and management of HSV infections.

PRINCIPLE

The S. typhoid/S. Para typhi Ag Rapid Test Device (Feces) is a lateral flow chromatographic immunoassay. The test cassette consists of: 1) a burgundy colored conjugate pad containing S.typhoid/S. Para typhi antibody conjugated with colloid gold, 2) a nitrocellulose membrane strip containing two test bands (S. typhoid/S. Para typhi bands) and a control band (C band). The S. typhoid band is pre-coated with monoclonal anti- S. typhoid for the detection of S. typhoid Ag, S. Para typhi band is pre-coated with reagents for the detection of S. Para typhi Ag , and the C band is pre-coated with goat anti mouse IgG. 
When an adequate volume of test specimen is dispensed into the sample well of the cassette, the test specimen migrates by capillary action across the test cassette. S. typhoid Ag if present in the patient specimen will bind to the S. typhoid Ab conjugates. The immunocomplex is then captured on the membrane by the pre-coated S. typhoid antibody, forming a burgundy colored S. typhoid band, indicating a S. typhoid positive test result. 
S.Para typhi Ag if present in the patient specimen will bind to the S. Para typhi Ab conjugates. The immunocomplex is then captured by the pre-coated S. Para typhi Ab on the membrane, forming a burgundy colored S. Para typhi Ab band, indicating a S. Para typhi Ab positive test result. Absence of any test bands suggests a negative result. The test contains an internal control (C band) which should exhibit a burgundy colored band of the immunocomplex of goat anti Mouse IgG/Mouse IgG-gold conjugate regardless of the color development on any of the test bands. 
Otherwise, the test result is invalid and the specimen must be retested with another device.


Product Detail

                • Brand: QL

                  Specimens: : Feces

                  Reading time:10 minutes.

                  Pack:20T

                  STORAGE: 2‐30°C

                  KIT COMPONENTS(Device)

                  • Test devices
                  • Droppers
                  • Single Buffer
                  • Package insert

 

  • ASSAY PROCEDURE

        • Typhoid Ag&S. typhoid/S. Para typhi Ag) 

          Bring tests, specimens, buffer and/or controls to room temperature (15-30°C) before use. 
          1. Specimen collection and pre-treatment: 
          1) Unscrew and remove the dilution tube applicator. Be careful not to spill or spatter solution from the tube. Collect specimens by inserting the applicator stick into at least 3 different sites of the feces. 
          2) Place the applicator back into the tube and screw the cap tightly. Be careful not to break the tip of the dilution tube. 
          3) Shake the specimen collection tube vigorously to mix the specimen and the extraction buffer. Specimens prepared in the specimen collection tube may be stored for 6 months at -20°C if not tested within 1 hour after preparation. 
          2. Testing 
          1) Remove the test from its sealed pouch, and place it on a clean, level surface. Label the test with patient or control identification. To obtain a best result, the assay should be performed within one hour. 
          2) Using a piece of tissue paper, remove the tip of the dilution tube. Hold the tube vertically and dispense 3 drops of solution into the specimen well (S) of the test device. 
          Avoid trapping air bubbles in the specimen well (S), and do not drop any solution in observation window. 
          As the test begins to work, you will see color move across the membrane. 
          3. Wait for the colored band(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes.


        INTERPRETATION OF ASSAY RESULT

        • NOTE:

      • 1.The intensity of the color in test region (T) may vary depending on the concentration of aimed substances present in the specimen. Therefore, any shade of color in the test region should be considered positive. Besides, the substances level cannot be determined by this qualitative test.
      • 2.Insufficient specimen volume, incorrect operation procedure, or performing expired tests are the most likely reasons for control band failure.
      •  


      The principle behind the HSV IgM Rapid Test Device is rooted in cutting-edge immunochromatographic techniques, designed to detect IgM antibodies to HSV in human serum, plasma, or whole blood samples within minutes. This rapid detection test is a crucial tool in the early stages of infection, facilitating timely decision-making and appropriate clinical interventions. Introducing the HSV IgM Rapid Test Device from QL Biotech, your go-to solution for fast, accurate HSV screening. Born from an urgent need to streamline the diagnostic process, our device bridges the gap between initial suspicion and definitive diagnosis. Utilizing a sophisticated yet user-friendly approach, the test employs a simple lateral flow assay format, ensuring results are both rapid and precise. This leap in diagnostic efficiency not only enhances patient care but also significantly reduces the anxiety associated with waiting for test results. Our commitment to innovation is reflected in every aspect of the HSV IgM Rapid Test Device, offering a glimmer of hope and a path forward for those in need of quick, dependable answers.