Experience the cutting-edge integration of HCV Cassette in our Strep A Rapid Test Device/strip – a significant breakthrough in rapid and accurate diagnosis of Strep A. This highly advanced immunoassay device boasts a lateral flow design, transcending traditional diagnostic methods to deliver reliable results from a simple throat swab. In essence, the HCV Cassette-integrated Strep A Rapid Test Device employs the lateral flow immunoassay system for qualitative detection. This mechanism focuses on the identification of the Strep A carbohydrate antigen prevalent in throat swabs, thereby providing a speedy and precise diagnosis. The implementation of the HCV Cassette in this diagnostic procedure boosts the accuracy and reliability of the results, making it an invaluable tool for healthcare facilities. This device strikes a perfect balance between simplicity and sophistication. The use of the HCV Cassette streamlines the process, offering an easy-to-use yet highly efficient diagnostic solution. This Strep A Rapid Test Device is designed to empower healthcare professionals with an accurate, immediate detection tool that helps save valuable time and resources. With a focus on simplicity, efficiency, and accuracy, our product rises above the conventional diagnostic methods.

PRINCIPLE

The Strep A Rapid Test Device/strip is a qualitative, lateral flow immunoassay for the detection of Strep A carbohydrate antigen in a throat swab. In this test, antibody specific to Strep A carbohydrate antigen is coated on the test line region of the test. During testing, the extracted throat swab specimen reacts with an antibody to Strep A that is coated onto particles. The mixture migrates up the membrane to react with the antibody to Strep A on the membrane and generate a color line in the test line region. The presence of this color line in the test line region indicates a positive result, while its absence indicates a negative result. To serve as a procedural control, a colored line will always appear in the control line region, indicating that proper volume of specimen has been added and membrane wicking has occurred.


Product Detail

    • Brand:QL

      Specimens: : Swab

      Reading time:5 minutes.

      Pack:20 T

      STORAGE: 2‐30°C

      KIT COMPONENTS(Device)

      •  •Test devices                            •Sterile swabs
      •  •Workstation                         • Strep A Reagent A (1M Sodium Nitrite )
      •  •Strep A Reagent B (0.4M Acetic Acid)      • Test tubes
      •  •Dropper tips                          • Package insert

       

      KIT COMPONENTS(strip)

      •  •Test strips                           • Sterile swabs
      •  •Workstation                          • Strep A Reagent A (1M Sodium Nitrite )
      •  •Strep A Reagent B (0.4M Acetic Acid)   • Test tubes
      •  •Package insert

 

PROCEDURE

    • Allow the test device, reagents, throat swab specimen, and/or controls to reach room temperature (15-30°C) prior to testing. 
      1. Remove the test device from the sealed foil pouch and use it as soon as possible. 
      Best results will be obtained if the test is performed immediately after opening the foil pouch. 
      2. Hold the Reagent A bottle vertically and add 4 full drops (approximately 240 µL) of Reagent A to an extraction test tube. Reagent A is red in color. Hold the 
      Reagent B bottle vertically and add 4 full drops (approximately 160 µL) to the tube. Reagent B is colorless. Mix the solution by gently swirling the extraction test tube. The addition of Reagent B to Reagent A changes the color of the solution from red to yellow. 
      3. Immediately add the throat swab to the extraction test tube of yellow solution. Agitate the swab 10 times in the tube. Leave the swab in the tube for 1 minute. Then press the swab against the side of the tube and squeeze the bottom of the tube as the swab is withdrawn. Discard the swab. 
      4. Fit the dropper tip on top of the extraction test tube. Place the test device on a clean and level surface. Add 3 full drops of solution (approx. 100 µL) to the specimen well (S) and then start the timer. 
      5. Wait for the colored line(s) to appear. Read the result at 5 minutes. Do not read the result after 10 minutes.

    INTERPRETATION OF RESULTS


    • NOTE:
    • The intensity of the color in test region (T) may vary depending on the concentration of aimed substances present in the specimen. Therefore, any shade of color in the test region should be considered positive. Besides, the substances level can not be determined by this qualitative test.
    • Insufficient specimen volume, incorrect operation procedure, or performing expired tests are the most likely reasons for control band failure.

     



    In addition to its functionality, the HCV Cassette-integrated Strep A Rapid Test Device also ensures the security and well-being of the patients. Understanding the importance of a swift and accurate diagnosis, we utilize the power of the HCV Cassette to offer reliable results that professionals can rely on. This commitment to quality and accuracy has made our Strep A Rapid Test Device a preferred choice among medical practitioners. Experience the integration of technology and healthcare with our advanced and efficient diagnostic solution. In a world where time is of the essence, our Strep A Rapid Test Device with integrated HCV Cassette, offers a fast, accurate, and reliable solution. Immerse yourself in a new era of efficient diagnosis with our advanced, easy-to-use, and remarkably accurate Strep A Rapid Test Device. Navigate the path of health and wellbeing with our reliable diagnostic tools.