Innovative Rapid Test HCV Test: Syphilis Detection Device/Strip by QL Biotech

Short Description:

The Syphilis Rapid Test Device (Whole Blood/Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of antibodies (IgG and IgM) to Treponema Pallidum (TP) in whole blood, serum or plasma to aid in the diagnosis of Syphilis.


Product Detail

Product Tags

At QL Biotech, we are pleased to introduce our cutting-edge Syphilis Rapid Test device/strip that incorporates our innovative Rapid Test HCV Test technology to deliver quick, reliable results with uncompromised accuracy. The fundamental principle behind our device is that it works as a qualitative membrane-based immunoassay. This technology is specifically designed to identify TP antibodies, including IgG and IgM, within whole blood, serum, or plasma. This meticulous detection method not only enhances the test's accuracy but also its ability to provide results promptly. QL Biotech prioritizes the delivery of comprehensive solutions to meet diverse testing requirements. With the use of our Rapid Test HCV Test technology, our Syphilis Rapid Test Device/Strip stands as a testament to our commitment to provide high-quality, efficient testing tools. Our device excels in offering quicker detection leading to timely intervention and management, a critical factor in dealing with such medical conditions.

PRINCIPLE

It is a qualitative membrane based immunoassay for the detection of TP antibodies (IgG and IgM) in whole blood, serum or plasma. In this test procedure, recombinant Syphilis antigen is immobilized in the test line region of the test.

After specimen is added to the specimen well of the device, it reacts with Syphilis antigen coated particles in the test. This mixture migrates chromatographically along the length of the test and interacts with the immobilized Syphilis antigen. The double antigen test format can detect both IgG and IgM in specimens. If the specimen contains TP antibodies, a colored line will appear in the test line region, indicating a positive result. If the specimen does not contain TP antibodies, a colored line will not appear in this region, indicating a negative result. To serve as a procedural control, a colored line will always appear in the control line region, indicating that proper volume of specimen has been added and membrane wicking has occurred.


Product Detail

      • Brand: QL

        1.Specimens: : Serum/Plasma

        Reading time:10 minutes.

        Pack:25 T

        STORAGE: 2‐30°C

        KIT COMPONENTS

        • Test devices/strips· Droppers
        • Buffer                 · Package insert

        Brand: QL

        2.Specimens: : Whole Blood/Serum/Plasma

        Reading time:10 minutes.

        Pack:25 T

        STORAGE: 2‐30°C

        KIT COMPONENTS

        • Test devices/strips· Droppers
        • Buffer                 · Package insert

 

DIRECTIONS FOR USE

  • 1.Syphilis Rapid Test Device/Strip (Serum/Plasma)
  • Allow the test, specimen, buffer and/or controls to reach room temperature (15‐30°C) prior to testing.
  • 1.Remove the test strip from the sealed pouch and use it as soon as possible. Best results will be obtained if the assay is performed within one hour.
  • 2.Hold the dropper vertically and transfer 2 drops of serum or plasma (approximately 50 mL) onto the Specimen Pad of the test strip, then add 1 drop of buffer (approximately 40 mL) and
  • start the timer.
  • 3.Wait for the colored line(s) to appear. Read results at 10 minutes. Do not interpret the result after 30 minutes.
  •  
  • 2.Syphilis Rapid Test Device(Whole Blood/Serum/Plasma)
  • Allow the test, specimen, buffer and/or controls to reach room temperature (15‐30°C)
  • prior to testing.
  • 1.Bring the pouch to room temperature before opening it. Remove the test device from the sealed pouch and use it as soon as possible.
  • 2.Place the device on a clean and level surface.
  • For Serum or Plasma specimen: Hold the dropper vertically and transfer 1 drop of serum or plasma (approximately 25mL) to the specimen well (S), then add 2 drops of buffer  (approximately 80mL), and start the timer.
  • For Whole Blood specimen: Hold the dropper vertically and transfer 2 drops of whole blood (approximately 80mL) to the specimen well (S), then add 1 drop of buffer (approximately 40 mL), and start the timer.
  • 3.Wait for the colored line(s) to appear. Read results at 10 minutes. Do not interpret the result after 30 minutes.

3.Syphilis Rapid Test Strip(Whole Blood/Serum/Plasma)

Allow the test, specimen, buffer and/or controls to reach room temperature (15‐30°C) prior to testing.

1.Remove the test strip from the sealed pouch and use it as soon as possible. Best results will be obtained if the assay is performed within one hour.
2.For Serum or Plasma specimens: Hold the dropper vertically and transfer 2 drops of serum or plasma (approximately 50 mL) onto the Specimen Pad of the test strip, then add 1 drop of buffer (approximately 40 mL) and start the timer.

For Venipuncture Whole Blood specimens: Hold the dropper vertically and transfer 2 drops of whole blood (approximately 50 mL) onto the Specimen Pad of the test strip, then add 2  drops of buffer (approximately 80 mL) and start the timer.

For Fingerstick Whole Bloodspecimens:

Fill the capillary tube and transfer approximately 50 mL (or 2 drops) of fingerstick whole blood specimen onto the Specimen Pad of the test strip, then add 2 drops of buffer (approximately 80 mL) and start the timer.

3.Wait for the colored line(s) to appear. Read results at 10 minutes. Do not interpret the result after 30 minutes.

INTERPRETATION OF RESULTS


    •  


    By encompassing the latest technology, our Syphilis Rapid Test Device/Strip is a leap forward in the field of rapid testing. Its simplicity, accuracy, and swiftness allow healthcare professionals to significantly streamline their testing process and ensure optimal patient care. In conclusion, QL Biotech's Syphilis Rapid Test device/strip, powered by our advanced Rapid Test HCV Test technology, offers high precision results while also saving time. By relying on our technology, health practitioners can stay ahead in their fight against this disease and provide the best possible care for their patients.