Malaria pf/pan Test Kit - Quick and Efficient Adenovirus Detection

Short Description:

The Adenovirus Rapid Test Device (Feces) is a rapid visual immunoassay for the qualitative presumptive detection of adenovirus in human fecal specimens. This kit is intended to be used as an aid in the diagnosis of adenovirus infection.


Product Detail

Product Tags

The Malaria pf/pan Test Kit is a comprehensive tool designed to facilitate the swift and reliable detection of adenovirus. This cutting-edge test device has been meticulously engineered to identify adenovirus presence simply through the visual interpretation of color development within its internal strip. Adenoviruses, being pathogenic entities, necessitate immediate detection to counteract any possible adverse effects. The Malaria pf/pan Test Kit, designating an innovation in the field of biotechnology, assures this rapid detection, tacitly promoting health and safety spheres. Crafted by QL Biotech, this easy-to-use device employs a simple process to provide reliable results, therefore expediting the overall diagnostic process. Our reputation of excellence in biotechnology is upheld by the Malaria pf/pan Test Kit’s unwavering performance, while providing the user with timely results that can crucially impact decision-making procedures.

PRINCIPLE

The Adenovirus Rapid Test Device (Feces) has been designed to detect adenovirus through visual interpretation of color development in the internal strip. The membrane was immobilized with anti-adenovirus on the test region. During the test, the specimen is allowed to react with colored anti-adnovirus antibodies colloidal gold conjugates, which were precoated on the sample pad of the test. The mixture then moves on the membrane by a capillary action, and interact with reagents on the membrane. If there were enough adenovirus in specimens, a colored band will form at the T region of the membrane. Presence of colored band indicates a positive result, while its absence indicates a negative result. Appearance of a colored band at the control region serves as a procedural control. This indicates that proper volume of specimen has been added and membrane wicking has occurred.


Product Detail

  • Brand:QL

    Specimens: : Feces

    Reading time:10 minutes.

    Pack:20 T

    STORAGE: 2‐30°C

    KIT COMPONENTS(Device)

    • Individually packed test devices
    • Specimens dilution tube with buffer
    • Disposable pipettes
    • Package insert

 

PROCEDURE

    • Bring tests, specimens, buffer and/or controls to room temperature (15-30°C) before use. 
      Bring tests, specimens, buffer and/or controls to room temperature (15-30°C) before use. 
      1. Specimen collection and pre-treatment: 
      1) Use the specimen collection container for specimen collection. Best results will be obtained if the assay is performed within 6 hours after collection. 
      2) For solid specimens: Unscrew and remove the dilution tube applicator. Be careful not to spill or spatter solution from the tube. Collect specimens by inserting the applicator stick into at least 3 different sites of the feces to collect approximately 50 mg of feces (equivalent to 1/4 of a pea). 
      For liquid specimens: Hold the pipette vertically, aspirate fecal specimens, and then transfer 2 drops (approximately 50 µL) into the specimen collection tube containing the extraction buffer. 
      3) Place the applicator back into the tube and screw the cap tightly. Be careful not to break the tip of the dilution tube. 
      4) Shake the specimen collection tube vigorously to mix the specimen and the extraction buffer. Specimens prepared in the specimen collection tube may be stored for 6 months at -20°C if 
      not tested within 1 hour after preparation. 
      2. Testing 
      1) Remove the test from its sealed pouch, and place it on a clean, level surface. Label the test with patient or control identification. To obtain a best result, the assay should be performed within one hour. 
      2) Using a piece of tissue paper, break the tip of the dilution tube. Hold the tube vertically and dispense 3 drops of solution into the specimen well (S) of the test device. 
      Avoid trapping air bubbles in the specimen well (S), and do not drop any solution in observation window. 
      As the test begins to work, you will see color move across the membrane. 
      3. Wait for the colored band(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes. 
      Note: If the specimen does not migrate (presence of particles), centrifuge the extracted specimens contained in the extraction buffer vial. Collect 80 µL of supernatant, dispense into the specimen well (S) of a new test device and start afresh following the instructions mentioned above.

    INTERPRETATION OF RESULTS


    POSITIVE: * A colored band appears in the control band region (C)and another colored band appears in the T band region.

    NEGATIVE: One colored band appears in the control band region (C). No band appears in the test band region (T).

    Control band fails to appear. Results from any test which has not produced a control band at the specified reading time must be discarded. Please review the procedure and repeat with a new test. If the problem persists, discontinue using the kit immediately and contact your local distributor.

    NOTE:

    The intensity of the color in test region (T) may vary depending on the concentration of aimed substances present in the specimen. Therefore, any shade of color in the test region should be considered positive. Besides, the substances level can not be determined by this qualitative test.
    Insufficient specimen volume, incorrect operation procedure, or performing expired tests are the most likely reasons for control band failure.

     



    While the primary intention of the Malaria pf/pan Test Kit remains the detection of adenovirus, it simultaneously aims to redefine simplicity and speed within the landscape of medical diagnostics. Our test kit sets a new benchmark in quality detection tools, densely packing efficiency, reliability, and sophistication into one compact device, well-suited for any laboratory environment. Experience the compelling advancement in adenovirus detection with the Malaria pf/pan Test Kit. The visual interpretation of color progression within the internal strip eliminates the need for extensive training or specialized knowledge, making it the optimal choice for a wide range of biomedical settings. With its swift operation and dependable results, the Malaria pf/pan Test Kit stands as a testament to QL Biotech’s commitment to improving diagnostics, enabling a better, healthier future for all.