Norovirus Rapid Test Device - Quick & Accurate Results
PRINCIPLE
The HCV Rapid Test Device (Whole Blood /Serum/Plasma) has been designed to detect antibodies to HCV through visual interpretation of color development in the internal strip. The membrane was immobilized with protein A on the test region. During the test, the specimen is allowed to react with colored recombinant HCV antigens colloidal gold conjugates, which were precoated on the sample pad of the test. The mixture then moves on the membrane by a capillary action, and interacts with reagents on the membrane. If there were enough HCV antibodies in specimens, a colored band will from at the test region of the membrane. Presence of this colored band indicates a positive result, while its absence indicates a negative result. Appearance of a colored band at the control region serves as a procedural control. This indicates that proper volume of specimen has been added and membrane wicking has occurred.
Product Detail
Brand: QL
Specimens: : Whole Blood/Serum/Plasma
Reading time:10 minutes.
Pack:25 T
STORAGE: 2‐30°C
KIT COMPONENTS:
Individually packed test strips
Disposable pipettes
Buffer
Package insert
PROCEDURE
- Bring tests, specimens, buffer and/or controls to room temperature (15-30°C) before use.
1. Remove the test from its sealed pouch, and place it on a clean, level surface. Label the device with patient or control identification. To obtain a best result, the assay should be performed within one hour.
2. For Serum or Plasma specimen: Hold the dropper vertically and transfer 2 drops of serum or plasma (approximately 50l ) and 1 drop buffer to the specimen well (S) of the test device, and start the timer.
For Venipuncture Whole Blood specimen: Hold the dropper vertically and transfer 2 drops of
venipuncture whole blood (approximately 50 l) to the specimen well (S) of the test device, then add 2 dropsof buffer and startthe timer.
For FingerstickWhole Bloodspecimen:
To use a capillary tube: Fill the capillary tube and transfer approximately 50l of fingerstick whole blood specimen to the specimen well (S) of the test device, then add 2 drops of buffer
and startthetimer.
To use hanging drop: Allow 2 hanging drop of fingerstick whole blood specimen (approximately 50l ) to fall into the center of the specimen well (S) on the test device, then add 2 dropsof buffer and startthe timer.
3. Wait for the red line(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes.
INTERPRETATION OF RESULTS
-
POSITIVERESULT:
* A colored band appears in the control band region (C) and another colored band appears in the T band region.
NEGATIVERESULT:
One colored band appears in the control band region (C). No band appears in the test band region (T).
INVALID RESULT:
Control band fails to appear. Results from any test which has not produced a control band at the specified reading time must be discarded. Please review the procedure and repeat with a new test.
If the problem persists, discontinue using the kit immediately and contact your local distributor.
NOTE:
1. The intensity of the color in test region (T) may vary depending on the concentration of aimed substances present in the specimen. Therefore, any shade of color in the test region should be considered positive. Besides, the substances level can not be determined by this qualitative test.
2. Insufficient specimen volume, incorrect operation procedure, or performing expired tests are the most likely reasons for control band failure.
Understanding the principle behind this innovative device begins with appreciating the meticulous design and research that have gone into its development. The test kit is based on the lateral flow immunoassay technique, a proven method for the qualitative detection of antibodies, in this case, those specific to the Norovirus. Upon applying the sample onto the test strip, the intricate workings of the device come into play. The sample migrates along the strip via capillary action, encountering labeled antibodies that bind specifically to Norovirus antigens, if present. This interaction culminates in a visible color change, signaling a positive result. The simplicity of the process, requiring no sophisticated equipment or extensive training, makes the Norovirus Rapid Test Device an indispensable tool in clinics, laboratories, and even remote field settings, where immediate diagnosis can drastically influence patient care decisions. With the prevalence of Norovirus and its rapid contagion among communities, having a quick and dependable testing method is more important than ever. QL Biotech's Norovirus Rapid Test Device stands as a testament to our commitment to advancing public health through innovative diagnostic solutions. Offering peace of mind through prompt and precise testing, this device is an essential asset for healthcare providers aiming to combat the spread of Norovirus effectively. Our dedication to quality, coupled with a deep understanding of the needs of both the medical community and the populations they serve, ensures that every product we offer, including the Norovirus Rapid Test Device, sets a new standard in diagnostic excellence.