Propel Your Typhoid Diagnostics with Our Advanced Typhoid Test Kit

Short Description:

The TB IgG/IgM Rapid Test Device (Whole Blood/Serum/Plasma) is a sandwich lateral flow chromatographic immunoassay for the qualitative detection of antibodies (IgG and IgM) anti-Mycobacterium Tuberculosis (M.TB) in human serum or plasma. It is intended to be used as a screening test and as an aid in the diagnosis of infection with M. TB. Any reactive specimen with the TB IgG/ IgM Rapid Test device must be confirmed with alternative testing method(s) and clinical findings.


Product Detail

Product Tags

Technology has significantly advanced in the medical field, providing us with exceptional tools for disease diagnosis and control. At QL Biotech, we have integrated this cutting-edge technology into our products, and our Typhoid Test Kit is no exception. It's designed to swiftly and accurately diagnose Typhoid, a feat achieved through the employment of the double antigen-sandwich technique. Our Tuberculosis IgG/IgM Rapid Test Device, now optimized as a Typhoid Test Kit, is a lateral flow chromatographic immunoassay built around this remarkable technique. This innovative kit simplifies typhoid detection, focusing on speed and accuracy, thereby affording healthcare professionals a reliable tool in their diagnostic arsenal. Running on the principle of the double antigen-sandwich technique, our Typhoid Test Kit offers an impressive accuracy level. The advanced design creates a remarkably swift reaction between the Typhoid IgG/IgM antibodies in the specimen and the Typhoid antigens immobilized on the membrane system. The flow-through interaction forms a colored complex, thus showcasing a positive result. With a simple operation, our kit ensures a quick and precise diagnosis within minutes. The QL Biotech Typhoid Test Kit is optimized to serve medical professionals in diverse healthcare settings, from high-tech laboratories to rural clinics. It has been successfully utilized in numerous testing scenarios, thereby validating its reliability and efficiency.

PRINCIPLE

The TB Antibody Rapid Test device is a lateral flow chromatographic immunoassay based on the principle of the double antigen–sandwich technique. The test cassette consists of: 1) a burgundy colored conjugate pad containing M.TB antigens conjugated with colloid gold (M.TB conjugates)and rabbit IgG‐gold conjugates, 2) a nitrocellulose membrane strip containing a test band (T band) and a control band (C band). The T band is pre‐coated with non‐conjugated M.TB antigens, and the C band is pre‐coated with goat anti‐rabbit IgG. When an adequate volume of test specimen is dispensed into the sample well of the cassette, the specimen migrates by capillary action across the cassette. The antibodies: either the IgG, the IgM to M. TB if present in the specimen will bind to the M.TB conjugates. The immunocomplex is then captured on the membrane by the pre‐coated M.TB antigens, forming a burgundy colored T band, indicating a M.TB Ab positive test result. Absence of the T band suggests a negative result. The test contains an internal control (C band) which should exhibit a burgundy colored band of the immunocomplex of goat anti‐rabbit IgG/rabbit IgG‐gold conjugate regardless the presence of any antibodies to M.TB. Otherwise, the test result is invalid and the specimen must be retested with another device.


Product Detail

          • Brand: QL

            Specimens: :Plasma/ Serum/ Whole Blood

            Reading time:1 minutes.

            Pack:25 T

            STORAGE: 2‐30°C

            KIT COMPONENTS

            • Test devices
            • Droppers
            • Buffer
            • Package insert

 

  • TEST PRINCIPLE

        • The TB IgG/IgM Rapid Test Device (Whole Blood/Serum/Plasma) is a lateral flow chromatographic immunoassay based on the principle of the double antigen–sandwich technique. The test cassette consists of: 1) a burgundy colored conjugate pad containing M.TB antigens conjugated with colloid gold (M.TB conjugates) and rabbit IgG‐gold conjugates, 2) a nitrocellulose membrane strip containing a test band (T band) and a control band (C band). The T band is pre‐coated with non‐conjugated M.TB antigens, and the C band is pre‐coated with goat anti‐rabbit IgG.

          When an adequate volume of test specimen is dispensed into the sample well of the cassette, the specimen migrates by capillary action across the cassette. The antibodies: either the IgG, the IgM to M. TB if present in the specimen will bind to the M.TB conjugates. The immunocomplex is then captured on the membrane by the pre‐coated M.TB antigens, forming a burgundy colored T band, indicating a M.TB Ab positive test result.

          Absence of the T band suggests a negative result. The test contains an internal control (C band) which should exhibit a burgundy colored band of the immunocomplex of goat anti‐rabbit IgG/rabbit IgG‐gold conjugate regardless the presence of any antibodies to M.TB. Otherwise, the test result is invalid and the specimen must be retested with another device.


        ASSAY PROCEDURE

        1. Bring the specimen and test components to room temperature. Place the test device  on a clean, flat surface. 
        2. Be sure to label the device with specimen’s ID number. 
        3. Fill the plastic dropper with the specimen. Holding the dropper vertically, dispense 2  drops (about 80 µL) of specimen into the sample well making sure that there are no  air bubbles. Then add 1 drop of buffer into the sample well. Set up timer. 
        4. Results can be read in 10 minutes. Positive results can be visible in as short as 1  minute. Don’t read result after 10 minutes. To avoid confusion, discard the test  device after interpreting the result.

        •  
        • INTERPRETATION OF ASSAY RESULT



          IgG Positive:* The colored line in the control line region (C) appears and a colored line appears in test line region IgG. The result is positive for Tuberculosis specific-IgG antibodies and is indicative of secondary Tuberculosis infection.

          IgM Positive:* The colored line in the control line region (C) appears and a colored line appears in test line region IgM. The result is positive for Tuberculosis specific-IgM and is probably indicative of primary Tuberculosis infection.

          IgG and IgM Positive:* The colored line in the control line region (C) appears and two colored lines should appear in test line regions IgG and IgM. The color intensities of the lines do not have to match. The result is positive for IgG & IgM antibodies and is indicative of secondary Tuberculosis infection.

          *NOTE: The intensity of the color in the test line region(s) will vary depending on the concentration of Tuberculosis antibodies in the specimen. Therefore, any shade of color in the test line region(s) should be considered positive.

          NEGATIVE RESULT:

          The colored line in the control line region (C) appears. No line appears in test line regions IgG or IgM.

          INVALID RESULT:

          Control line (C) falls to appear. Insufficient buffer volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the procedure with a new test device. If the problem persists, discontinue using the test kit immediately and contact your local distributor.
           



        In a world where rapid and accurate diagnosis is key in disease management, our Typhoid Test Kit stands as a significant stride in the right direction. Now, clinical practitioners can confidently make faster, informed decisions about their patient's health, reinforcing our commitment to better healthcare for all. Trust QL Biotech's Typhoid Test Kit for a revolutionary, accurate, and swift Typhoid detection solution. Together, we are transforming healthcare, one test at a time.