In the rapidly evolving medical landscape, QL Biotech stands at the forefront of innovation, particularly with our groundbreaking HBsAg Whole Blood Rapid Test Strip. Designed with precision and user convenience in mind, this product marks a significant milestone in the detection of Hepatitis B virus (HBV) antigens in human blood. The principle behind the HBsAg Whole Blood Rapid Test Strip is both innovative and straightforward - utilizing a unique blend of sensitivity and specificity to detect the presence of Hepatitis B surface antigen (HBsAg) in whole blood. This method not only simplifies the screening process but also ensures rapid and precise results. Unlike traditional testing methods that require complex procedures and extended waiting periods, our rapid test strip delivers results in a matter of minutes, facilitating quick decision-making and early intervention.

PRINCIPLE

The HBsAg Rapid Test Device (Serum/Plasma) has been designed to detect the HBsAg through visual interpretation of color development in the strip. The membrane was immobilized with anti‐ HBsAg antibodies on the test region. During the test, the specimen is allowed to react with colored anti‐HBsAg antibodies colloidal gold conjugates, which were precoated on the sample pad of the test. The mixture then moves on the membrane by a capillary action, and interact with reagents on the membrane. If there were enough HBsAg in specimens, a colored band will from at the test region of the membrane. Presence of this colored band indicates a positive result, while its

absence indicates a negative result. Appearance of a colored band at the control region serves as a procedural control. This indicates that proper volume of specimen has been added and membrane wicking has occurred.


Product Detail

Brand: QL

Specimens: : Serum/Plasma

Reading timeDevice15 minutes./ Strip 10 minutes.

Pack:25 T

STORAGE: 2‐30°C

KIT COMPONENTS

1

Individually packed test devices

Disposable pipettes

Buffer

Package insert

2

Individually packed test strips 

Disposable pipettes

Package insert

 

PROCEDURE

    • HBsAg Rapid Test Strip
      Bring tests, specimens and/or controls to room temperature (15‐30°C) before use. 
      1. Transfer 3 drop of specimen to a specimen reaction tube with a disposable pipette provided in the kit.
      2. Remove the test from its sealed pouch and use it as soon as possible. To obtain a best result, the assay should be performed within one hour. 
      3. Hold the strip at the handle with the product name imprints. Do not touch the membrane part of the strip to avoid contamination. 
      4. Dip the test strip vertically in the specimen for at least 10‐15 seconds. Do not pass the maximum line (MAX) on the test strip when immersing the strip. 
      As the test begins to work, you will see color move across the membrane. 
      5. Take the strip out of the specimen afterwards and place it on a non‐absorbents flat surface. 
      Start the timer and wait for the colored line(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes.
      HBsAg Rapid Test Device
      Bring tests, specimens and/or controls to room temperature (15‐30°C) before use. 
      1. Remove the test from its sealed pouch, and place it on a clean, level surface. Label the test with patient or control identification. To obtain a best result, the assay should be performed 
      within one hour
      Transfer 2 drops of serum/plasma to the specimen well of the device with a disposable pipette provided in the kit, then add 1 drop of buffer and start the timer. 
      Avoid trapping air bubbles in the specimen well (S), and do not drop any solution in observation window. 
      As the test begins to work, you will see color move across the membrane. 
      2. Wait for the colored band(s) to appear. The result should be read at 15 minutes. Do not interpret the result after 20 minutes.

    INTERPRETATION OF RESULTS






    What sets the HBsAg Whole Blood Rapid Test Strip apart is its meticulous design which allows for the visual interpretation of results. When a sample is applied, the strip undergoes a color change to indicate the presence or absence of HBsAg. This intuitive approach eliminates the need for sophisticated equipment or specialized training, making it an invaluable tool in various settings – from advanced healthcare facilities to remote field operations. Moreover, the capacity to use whole blood samples adds a layer of convenience, allowing for broader screening efforts that can reach more individuals and potentially curb the spread of Hepatitis B. In crafting this comprehensive solution, QL Biotech has meticulously considered every aspect of user experience and diagnostic accuracy. The HBsAg Whole Blood Rapid Test Strip is more than just a test; it is a beacon of hope for millions worldwide, offering a quicker, more accessible means of detection that could significantly impact global health outcomes. This product embodies our commitment to excellence and innovation in biotechnology, aiming to enhance the efficiency of medical diagnostics and contribute to the betterment of public health.