Quick Detection with Strep A Rapid Test Kit - QL Biotech
PRINCIPLE
It is a qualitative membrane based immunoassay for the detection of TP antibodies (IgG and IgM) in whole blood, serum or plasma. In this test procedure, recombinant Syphilis antigen is immobilized in the test line region of the test.
After specimen is added to the specimen well of the device, it reacts with Syphilis antigen coated particles in the test. This mixture migrates chromatographically along the length of the test and interacts with the immobilized Syphilis antigen. The double antigen test format can detect both IgG and IgM in specimens. If the specimen contains TP antibodies, a colored line will appear in the test line region, indicating a positive result. If the specimen does not contain TP antibodies, a colored line will not appear in this region, indicating a negative result. To serve as a procedural control, a colored line will always appear in the control line region, indicating that proper volume of specimen has been added and membrane wicking has occurred.
Product Detail
-
-
-
Brand: QL
1.Specimens: : Serum/Plasma
Reading time:10 minutes.
Pack:25 T
STORAGE: 2‐30°C
KIT COMPONENTS
- Test devices/strips· Droppers
- Buffer · Package insert
Brand: QL
2.Specimens: : Whole Blood/Serum/Plasma
Reading time:10 minutes.
Pack:25 T
STORAGE: 2‐30°C
KIT COMPONENTS
- Test devices/strips· Droppers
- Buffer · Package insert
-
-
DIRECTIONS FOR USE
- 1.Syphilis Rapid Test Device/Strip (Serum/Plasma)
- Allow the test, specimen, buffer and/or controls to reach room temperature (15‐30°C) prior to testing.
- 1.Remove the test strip from the sealed pouch and use it as soon as possible. Best results will be obtained if the assay is performed within one hour.
- 2.Hold the dropper vertically and transfer 2 drops of serum or plasma (approximately 50 mL) onto the Specimen Pad of the test strip, then add 1 drop of buffer (approximately 40 mL) and
- start the timer.
- 3.Wait for the colored line(s) to appear. Read results at 10 minutes. Do not interpret the result after 30 minutes.
- 2.Syphilis Rapid Test Device(Whole Blood/Serum/Plasma)
- Allow the test, specimen, buffer and/or controls to reach room temperature (15‐30°C)
- prior to testing.
- 1.Bring the pouch to room temperature before opening it. Remove the test device from the sealed pouch and use it as soon as possible.
- 2.Place the device on a clean and level surface.
- For Serum or Plasma specimen: Hold the dropper vertically and transfer 1 drop of serum or plasma (approximately 25mL) to the specimen well (S), then add 2 drops of buffer (approximately 80mL), and start the timer.
- For Whole Blood specimen: Hold the dropper vertically and transfer 2 drops of whole blood (approximately 80mL) to the specimen well (S), then add 1 drop of buffer (approximately 40 mL), and start the timer.
- 3.Wait for the colored line(s) to appear. Read results at 10 minutes. Do not interpret the result after 30 minutes.
3.Syphilis Rapid Test Strip(Whole Blood/Serum/Plasma)
Allow the test, specimen, buffer and/or controls to reach room temperature (15‐30°C) prior to testing.
1.Remove the test strip from the sealed pouch and use it as soon as possible. Best results will be obtained if the assay is performed within one hour.2.For Serum or Plasma specimens: Hold the dropper vertically and transfer 2 drops of serum or plasma (approximately 50 mL) onto the Specimen Pad of the test strip, then add 1 drop of buffer (approximately 40 mL) and start the timer.
For Venipuncture Whole Blood specimens: Hold the dropper vertically and transfer 2 drops of whole blood (approximately 50 mL) onto the Specimen Pad of the test strip, then add 2 drops of buffer (approximately 80 mL) and start the timer.
For Fingerstick Whole Bloodspecimens:
Fill the capillary tube and transfer approximately 50 mL (or 2 drops) of fingerstick whole blood specimen onto the Specimen Pad of the test strip, then add 2 drops of buffer (approximately 80 mL) and start the timer.
3.Wait for the colored line(s) to appear. Read results at 10 minutes. Do not interpret the result after 30 minutes.INTERPRETATION OF RESULTS
Crafted meticulously with accuracy and ease of use in mind, this qualitative membrane-based immunoassay has been engineered to deliver results with unmatched precision. The core principle of our test lies in its ability to rapidly identify the presence of TP antibodies, a crucial step in combating the spread of syphilis. By facilitating a straightforward and efficient testing method, our Syphilis Rapid Test Device/Strip ensures that medical practitioners can offer their patients prompt and reliable diagnostic services. This is particularly critical in the fast-paced medical environments of today, where time is of the essence and early detection can dramatically alter patient outcomes. At QL Biotech, we understand the critical need for reliable diagnostic tools in the fight against infectious diseases. Our Syphilis Rapid Test Device/Strip stands as a testament to our dedication to innovation, quality, and the enhancement of public health safety. By incorporating our test into your healthcare practice, you're not just acquiring a product; you're embracing a solution that promises to streamline the diagnostic process, reduce wait times, and ultimately, improve patient care. Our commitment to excellence ensures that each strip we produce meets the highest standards of diagnostic accuracy, providing you with confidence in every result.