Quick H Pylori Test Strips for Accurate Detection - QL Biotech

Short Description:

The H. Pylori Ag Rapid Test Strip (Feces) is a rapid chromatographic immunoassay for the qualitative detection of antigens to H. Pylori in feces to aid in the diagnosis of H. Pylori infection.


Product Detail

Product Tags

In the landscape of medical diagnostics, the quest for efficiency, accuracy, and reliability in testing for infections like Helicobacter pylori (H. pylori) is paramount. QL Biotech proudly introduces its flagship product - the H.Pylori Ag Rapid Test Device/Strip, a leap forward in gastrointestinal infection diagnostics. Our innovative solution promises not just to meet but exceed the expectations of healthcare professionals and patients alike, offering a seamless pathway to diagnosing one of the most common bacterial infections worldwide. Understanding H. Pylori and Its Impact on Health: Helicobacter pylori, a bacterium found in the stomach lining, has been identified as a primary cause of several gastrointestinal diseases, including peptic ulcers, gastritis, and in some cases, gastric cancer. The insidious nature of H. pylori lies in its ability to reside in the stomach undetected for years, leading to chronic conditions if left untreated. Early detection through reliable diagnostic methods like the H.Pylori Ag Rapid Test Strips is critical to managing and preventing the severe consequences of H. pylori infection. QL Biotech's H.Pylori Ag Rapid Test Device/Strip: A Closer Look: At the heart of our product is the principle of immunoassay-based detection, leveraging the body's immune response to H. pylori. Our test strips are meticulously designed to detect antigens of H. pylori in human feces with high specificity and sensitivity, offering results in a matter of minutes. This rapid test device is a testament to QL Biotech's commitment to innovation and accuracy, providing a non-invasive, user-friendly, and highly effective solution for H. pylori testing. The strip format allows for easy handling and disposal, ensuring a sanitary testing process.

PRINCIPLE

The H. Pylori Ag Rapid Test Devic/Strip (Feces) is a non‐invasive lateral flow assay, rapid, precise and easy to perform.This test makes use of specific antibodies against H. Pylori antigen adsorbed onto a reactive membrane. If H. Pylori is present in stool specimen, the specific antigen is bound by the second antibody which is conjugated with colloidal gold particles. A generic antibody, fixed onto the reactive membrane, in shape of the band, is able to capture the second conjugated antibody, assuring the correctness of the test performance.


Product Detail

Brand: QL

Specimens: : Feces

Reading time:10 minutes.

Pack:25 T

STORAGE: 2‐30°C

KIT COMPONENTS(Device)

Individually packed Test Devices/Strips

Each test contains a strip with colored conjugates and reactive reagents pre-spreaded at the

corresponding regions

Tubes with buffer

Phosphate buffered saline and preservative, extract the samples

Package insert

For operation instruction

PROCEDURE

    • Bring tests, specimens, buffer and/or controls to room temperature (15-30°C) before use. 
      1. Specimen collection and pre-treatment: 
      1) Unscrew and remove the dilution tube applicator. Be careful not to spill or spatter solution from the tube. Collect specimens by inserting the applicator stick into at least 3 different sites of the feces. 
      2) Place the applicator back into the tube and screw the cap tightly. Be careful not to break the tip of the dilution tube. 
      3) Shake the specimen collection tube vigorously to mix the specimen and the extraction buffer. Specimens prepared in the specimen collection tube may be stored for 6 months at -20°C if 
      not tested within 1 hour after preparation. 
      2. Testing 
      1) Remove the test from its sealed pouch, and place it on a clean, level surface. Label the test with patient or control identification. To obtain a best result, the assay should be performed within one hour. 
      2) Using a piece of tissue paper, remove the tip of the dilution tube. Hold the tube vertically and dispense 3 drops of solution into the sample well of the Test Device. 
      Avoid trapping air bubbles onto the sample pad, and do not drop any solution in observation window. 
      As the test begins to work, you will see color move across the membrane. 
      3. Wait for the colored band(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes.

    INTERPRETATION OF RESULTS


    • POSITIVE RESULT: 
      A colored band appears in the control band region (C) and another colored band appears in the T band region 
      NEGATIVE RESULT: 
      One colored band appears in the control band region (C). No band appears in the test band region (T) 
      INVALID RESULT: 
      Control band fails to appear. Results from any test which has not produced a control band at the specified reading time must be discarded. Please review the procedure and repeat with a new test. If the problem persists, discontinue using the kit immediately and contact your local distributor.
      NOTE: 
      1. The intensity of the color in test region (T) may vary depending on the concentration of aimed substances present in the specimen. Therefore, any shade of color in the test region should be considered positive. Besides, the substances level can not be determined by this qualitative test. 
      2. Insufficient specimen volume, incorrect operation procedure, or performing expired tests are the most likely reasons for control band failure.




    Crafted to address the needs of various settings—be it clinics, laboratories, or remote areas without sophisticated medical equipment—our H.Pylori Ag Rapid Test Device/Strip stands as a beacon of rapid diagnostics. Its ease of use makes it accessible to healthcare professionals across different levels of expertise, ensuring that a broad audience can benefit from its capabilities. Furthermore, the device's rapid turnaround time for results diminishes the anxiety of waiting, facilitating quicker decision-making in clinical management and treatment of H. pylori infections. In conclusion, QL Biotech's H.Pylori Ag Rapid Test Device/Strip is not just a diagnostic tool; it's a potentially life-changing solution for millions at risk of serious gastrointestinal diseases caused by H. pylori. With a dedication to excellence, precision, and accessibility, QL Biotech is at the forefront of transforming the landscape of infectious disease diagnostics, one test at a time.