Quick HIV AG Rapid Test Kit for Early Diagnosis and Infection Management

Short Description:

Human Immunodeficiency Virus (HIV) Ab & P24 Ag Rapid Test Device (Whole Blood/Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of antibodies to HIV 1 and/or HIV 2 and P24 antigen in whole blood, serum or plasma.


Product Detail

Product Tags

HIV is a devastating illness that has impacted numerous lives worldwide. Early detection is crucial for both disease management and preventing further transmission. Here at QL Biotech, we provide a swift, accurate, and convenient solution – the HIV AG Rapid Test kit. The HIV AG Rapid Test kit is a qualitative membrane immunoassay device. It's specifically designed for the meticulous detection of HIV 1&2 antibodies and P24 antigen in various specimens - whole blood, serum, or plasma. Our test kit does more than just uncover the presence of HIV-related antibodies. It also determines the P24 antigen, an early marker of HIV infection, which sometimes becomes visible before antibodies are produced. Our device employs a straightforward operating principle. In the membrane of the test device, we've implanted colloidal gold conjugates of recombinant antigens (HIV 1&2 and P24). When a specimen is added to the sample well, it reacts with the colloidal gold conjugates, creating a visible line in the test region if antibodies to HIV 1&2 or P24 antigen are present.

PRINCIPLE

Human Immunodeficiency Virus (HIV) Ab & P24 Ag Rapid Test Device (Whole Blood/Serum/Plasma) is a qualitative, membrane based immunoassay for the detection of antibodies to HIV 1&2 and P24 antigen in whole blood, serum or plasma. The membrane is precoated with recombinant HIV antigens to HIV 1&2 antibody and P24 antibody to HIV P24 antigen. During testing, the whole blood, serum or plasma specimen reacts with HIV antigen or P24 antibody coated particles in the test strip. The mixture then migrates upward on the membrane chromatographically by capillary action and reacts with recombinant HIV antigen or P24 antibody on the membrane in the test line regions. If the specimen contains antibodies to HIV 1 and/or HIV 2 and/or P24 antigen, a colored line will appear in the test line region indicating a positive result. If the specimen does not contain HIV 1 and/or HIV 2 antibodies and/or P24 antigen, no colored line will appear in the test line region indicating a negative result. To serve as a procedural control, a colored line will always appear in the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred.


MATERIALS

Materials Provided
● Test devices ● Disposable specimen droppers
● Buffer ● Package insert
Materials Required But Not Provided
● Specimen collection containers ● Lancets (for fingerstick whole blood only)
● Centrifuge (for plasma only) ● Timer
● Disposable heparinized capillary tubes and dispensing bulb (for fingerstick whole blood only)

 

DIRECTIONS FOR USE

    • ● Test devices 
      ● Disposable specimen droppers 
      ● Buffer 
      ● Package insert 
      Materials Required But Not Provided 
      ● Specimen collection containers 
      ● Lancets (for fingerstick whole blood only) 
      ● Centrifuge (for plasma only) 
      ● Timer 
      ● Disposable heparinized capillary tubes and dispensing bulb (for fingerstick whole blood only)


    PERFORMANCE CHARACTERISTICS

    Sensitivity

    Human Immunodeficiency Virus (HIV) Ab & P24 Ag Rapid Test Device (Whole

    Blood/Serum/Plasma) has been tested by anti-HIV 1 low titer performance panel, anti-HIV 2 performance panel and anti-HIV 1 seroconversion panel (Boston Biomedica, Inc.). And it has also been compared with leading commercial EIA HIV test on clinical specimens. The results show that

    HIV 1&2 Human Immunodeficiency Virus Rapid Test Device (Whole Blood/Serum/Plasma) is very sensitive to HIV 1 and/or HIV 2 antibodies.

    Specificity

    The specificity of the test is comparable to a leading commercial HIV EIA test. Human Immunodeficiency Virus (HIV) Ab & P24 Ag Rapid Test Device (Whole Blood/Serum/Plasma) is highly specific for anti-HIV 1 and/or HIV 2 compared to a leading commercial HIV EIA test.

    Relative Sensitivity: 99.9% (99.3%-100.0%)*Relative Specificity: 99.6% (99.1%-99.9%)*

    Relative Accuracy: 99.8% (99.4%-99.9%)* * 95% Confidence Interval

    Precision

    Intra Assay

    Within-run precision has been determined by using 15 replicates of three specimens: a negative, a low positive and a high positive. The negative, low positive and high positive values were correctly identified 99.5% of the time.

    Inter-Assay

    Between-run precision has been determined by 15 independent assays on the same three specimens: a negative, a low positive and a high positive. Three different lots of Human

    Immunodeficiency Virus (HIV) Ab & P24 Ag Rapid Test Device (Whole Blood/Serum/Plasma) have been tested using negative, low positive and high positive specimens. The specimens were correctly identified 99.5% of the time.

     



    QL Biotech's HIV AG Rapid Test kit stands out for its accuracy and convenience. The simplicity of our test kit means you can use it regardless of your technical skills or medical background. Yet, the reliability of its results matches those of more complex and time-consuming laboratory tests. In conclusion, the HIV AG Rapid Test kit from QL Biotech is a reliable, efficient tool for the detection of HIV 1&2 antibodies and P24 antigen. It combines precision, simplicity, and speed, making it a smart choice for those wishing to take control of their health. It's more than just a test kit; it's a comprehensive solution for HIV detection and management. Embrace the high-quality and reliable HIV testing solution that QL Biotech provides. With this, we are confident that our HIV AG Rapid Test kit will be a valuable addition to your health management tools. Get tested today. It's quick, it's simple and it's reliable. It's the HIV AG Rapid Test kit from QL Biotech.