Quick, Reliable H Pylori Test Strips by QL Biotech for Rapid Detection

Short Description:

The H. Pylori Ag Rapid Test Strip (Feces) is a rapid chromatographic immunoassay for the qualitative detection of antigens to H. Pylori in feces to aid in the diagnosis of H. Pylori infection.


Product Detail

Product Tags

Experience the power of advanced medical technology with QL Biotech's H Pylori Test Strips. Designed for rapid, accurate detection of Helicobacter pylori antigens, these test strips have been developed to cater to the rigorous demands of modern healthcare standards. Our H Pylori Test Strips are built around an operating principle that ensures the utmost accuracy and speed. Lace with a robust testing methodology, these strips use advanced chemical reagents and top-tier medical technology to accurately identify the H.Pylori antigen in human stool specimens. Aided by a one-step procedure, these strips facilitate instant detection, enabling healthcare professionals to make swift and informed decisions. QL Biotech stands tall as a leading figure in the biotechnology industry. We remain committed to providing innovative solutions that not only meet but exceed medical industry requirements. Our H Pylori Test Strips are a testament to our dedication and commitment. They're not just quick, they're accurate, making them the perfect fit for those who value reliability and speed in equal measures.

PRINCIPLE

The H. Pylori Ag Rapid Test Devic/Strip (Feces) is a non‐invasive lateral flow assay, rapid, precise and easy to perform.This test makes use of specific antibodies against H. Pylori antigen adsorbed onto a reactive membrane. If H. Pylori is present in stool specimen, the specific antigen is bound by the second antibody which is conjugated with colloidal gold particles. A generic antibody, fixed onto the reactive membrane, in shape of the band, is able to capture the second conjugated antibody, assuring the correctness of the test performance.


Product Detail

Brand: QL

Specimens: : Feces

Reading time:10 minutes.

Pack:25 T

STORAGE: 2‐30°C

KIT COMPONENTS(Device)

Individually packed Test Devices/Strips

Each test contains a strip with colored conjugates and reactive reagents pre-spreaded at the

corresponding regions

Tubes with buffer

Phosphate buffered saline and preservative, extract the samples

Package insert

For operation instruction

PROCEDURE

    • Bring tests, specimens, buffer and/or controls to room temperature (15-30°C) before use. 
      1. Specimen collection and pre-treatment: 
      1) Unscrew and remove the dilution tube applicator. Be careful not to spill or spatter solution from the tube. Collect specimens by inserting the applicator stick into at least 3 different sites of the feces. 
      2) Place the applicator back into the tube and screw the cap tightly. Be careful not to break the tip of the dilution tube. 
      3) Shake the specimen collection tube vigorously to mix the specimen and the extraction buffer. Specimens prepared in the specimen collection tube may be stored for 6 months at -20°C if 
      not tested within 1 hour after preparation. 
      2. Testing 
      1) Remove the test from its sealed pouch, and place it on a clean, level surface. Label the test with patient or control identification. To obtain a best result, the assay should be performed within one hour. 
      2) Using a piece of tissue paper, remove the tip of the dilution tube. Hold the tube vertically and dispense 3 drops of solution into the sample well of the Test Device. 
      Avoid trapping air bubbles onto the sample pad, and do not drop any solution in observation window. 
      As the test begins to work, you will see color move across the membrane. 
      3. Wait for the colored band(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes.

    INTERPRETATION OF RESULTS


    • POSITIVE RESULT: 
      A colored band appears in the control band region (C) and another colored band appears in the T band region 
      NEGATIVE RESULT: 
      One colored band appears in the control band region (C). No band appears in the test band region (T) 
      INVALID RESULT: 
      Control band fails to appear. Results from any test which has not produced a control band at the specified reading time must be discarded. Please review the procedure and repeat with a new test. If the problem persists, discontinue using the kit immediately and contact your local distributor.
      NOTE: 
      1. The intensity of the color in test region (T) may vary depending on the concentration of aimed substances present in the specimen. Therefore, any shade of color in the test region should be considered positive. Besides, the substances level can not be determined by this qualitative test. 
      2. Insufficient specimen volume, incorrect operation procedure, or performing expired tests are the most likely reasons for control band failure.




    Our H Pylori Test Strips are a game-changer, promising superior quality, accuracy, and speedy results. Trust in QL Biotech to deliver reliable solutions for all your testing needs. With our H Pylori Test Strips, rapid detection has never been easier or more secure. Discover the QL Biotech difference today. Let our H Pylori Test Strips guide you towards rapid results, improved decisions, and ultimately, better health. Experience the power of precision, speed, and reliability with QL Biotech's H Pylori Test Strips. It's not just a test strip, it's a commitment to health.

  • Previous: