Quick & Reliable Home Use Dengue Igg/Igm Test Kit by QL Biotech

Short Description:

The Adenovirus Rapid Test Device (Feces) is a rapid visual immunoassay for the qualitative presumptive detection of adenovirus in human fecal specimens. This kit is intended to be used as an aid in the diagnosis of adenovirus infection.


Product Detail

Product Tags

In an era where health awareness and immediate diagnostics are paramount, QL Biotech is proud to introduce a groundbreaking solution for rapid, at-home testing: The Home Use Dengue Igg/Igm Test Kit. This innovative product revolutionizes the way individuals can monitor their health, providing fast and reliable results from the comfort of their own homes. Understanding the critical need for timely detection of dengue fever, a prevalent and potentially severe viral illness transmitted by mosquitoes, QL Biotech has meticulously developed this test kit to cater to the needs of individuals worldwide. Dengue fever symptoms often mimic those of other illnesses, making early detection and differentiation crucial for effective management and treatment. The Home Use Dengue Igg/Igm Test Kit empowers users to take proactive steps in monitoring potential infections, significantly reducing the anxiety and uncertainty that can accompany the wait for professional diagnostic results. Our Adenovirus Rapid Test Device, upon which the Home Use Dengue Igg/Igm Test Kit is modeled, employs a similar principle of operation, ensuring user-friendly application and precise results. By utilizing a small sample - in this case, a drop of blood - and following simple step-by-step instructions, individuals can achieve visual confirmation of the presence of dengue fever markers within minutes. The kit is designed to detect both IgG and IgM antibodies, offering insights into whether the infection is recent or occurred in the past. This level of distinction is invaluable for healthcare providers in determining the most appropriate course of action.

PRINCIPLE

The Adenovirus Rapid Test Device (Feces) has been designed to detect adenovirus through visual interpretation of color development in the internal strip. The membrane was immobilized with anti-adenovirus on the test region. During the test, the specimen is allowed to react with colored anti-adnovirus antibodies colloidal gold conjugates, which were precoated on the sample pad of the test. The mixture then moves on the membrane by a capillary action, and interact with reagents on the membrane. If there were enough adenovirus in specimens, a colored band will form at the T region of the membrane. Presence of colored band indicates a positive result, while its absence indicates a negative result. Appearance of a colored band at the control region serves as a procedural control. This indicates that proper volume of specimen has been added and membrane wicking has occurred.


Product Detail

  • Brand:QL

    Specimens: : Feces

    Reading time:10 minutes.

    Pack:20 T

    STORAGE: 2‐30°C

    KIT COMPONENTS(Device)

    • Individually packed test devices
    • Specimens dilution tube with buffer
    • Disposable pipettes
    • Package insert

 

PROCEDURE

    • Bring tests, specimens, buffer and/or controls to room temperature (15-30°C) before use. 
      Bring tests, specimens, buffer and/or controls to room temperature (15-30°C) before use. 
      1. Specimen collection and pre-treatment: 
      1) Use the specimen collection container for specimen collection. Best results will be obtained if the assay is performed within 6 hours after collection. 
      2) For solid specimens: Unscrew and remove the dilution tube applicator. Be careful not to spill or spatter solution from the tube. Collect specimens by inserting the applicator stick into at least 3 different sites of the feces to collect approximately 50 mg of feces (equivalent to 1/4 of a pea). 
      For liquid specimens: Hold the pipette vertically, aspirate fecal specimens, and then transfer 2 drops (approximately 50 µL) into the specimen collection tube containing the extraction buffer. 
      3) Place the applicator back into the tube and screw the cap tightly. Be careful not to break the tip of the dilution tube. 
      4) Shake the specimen collection tube vigorously to mix the specimen and the extraction buffer. Specimens prepared in the specimen collection tube may be stored for 6 months at -20°C if 
      not tested within 1 hour after preparation. 
      2. Testing 
      1) Remove the test from its sealed pouch, and place it on a clean, level surface. Label the test with patient or control identification. To obtain a best result, the assay should be performed within one hour. 
      2) Using a piece of tissue paper, break the tip of the dilution tube. Hold the tube vertically and dispense 3 drops of solution into the specimen well (S) of the test device. 
      Avoid trapping air bubbles in the specimen well (S), and do not drop any solution in observation window. 
      As the test begins to work, you will see color move across the membrane. 
      3. Wait for the colored band(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes. 
      Note: If the specimen does not migrate (presence of particles), centrifuge the extracted specimens contained in the extraction buffer vial. Collect 80 µL of supernatant, dispense into the specimen well (S) of a new test device and start afresh following the instructions mentioned above.

    INTERPRETATION OF RESULTS


    POSITIVE: * A colored band appears in the control band region (C)and another colored band appears in the T band region.

    NEGATIVE: One colored band appears in the control band region (C). No band appears in the test band region (T).

    Control band fails to appear. Results from any test which has not produced a control band at the specified reading time must be discarded. Please review the procedure and repeat with a new test. If the problem persists, discontinue using the kit immediately and contact your local distributor.

    NOTE:

    The intensity of the color in test region (T) may vary depending on the concentration of aimed substances present in the specimen. Therefore, any shade of color in the test region should be considered positive. Besides, the substances level can not be determined by this qualitative test.
    Insufficient specimen volume, incorrect operation procedure, or performing expired tests are the most likely reasons for control band failure.

     



    Moreover, our commitment to quality and accuracy does not end with the product's design. Each Home Use Dengue Igg/Igm Test Kit undergoes rigorous quality control processes to ensure reliability and safety for all users. This dedication to excellence makes the kit an essential tool for those living in or traveling to regions where dengue fever is a concern. In summary, the Home Use Dengue Igg/Igm Test Kit from QL Biotech stands as a testament to our commitment to innovative health solutions. Offering rapid results, ease of use, and unparalleled accuracy, this test kit is an indispensable resource for individuals seeking to stay informed about their health status concerning dengue fever. With QL Biotech, you can rest assured that managing health concerns just got a little easier, bringing peace of mind and confidence to your healthcare routine.