Quick & Reliable Rubella IgG/IgM Rapid Test Kits by QL Biotech

Short Description:

The H. Pylori Ab Rapid Test is a rapid chromatographic immunoassay for the qualitative detection of antibodies to H. Pylori in serum or plasma to aid in the diagnosis of H.


Product Detail

Product Tags

QL Biotech is proud to unveil its state-of-the-art diagnostic solution aimed at revolutionizing the detection of Rubella IgG/IgM antibodies - the Rubella IgG/IgM Rapid Test Strip/Device. In the realm of infectious diseases, timely and accurate diagnosis is paramount. Our product is meticulously designed to cater to this need, offering a swift and reliable testing method for healthcare professionals and their patients. The foundation of our Rubella IgG/IgM Rapid Test Strip/Device lies in its innovative technology that harnesses the power of advanced immunochromatographic assays. This cutting-edge principle enables the detection of Rubella IgG/IgM antibodies in human blood, serum, or plasma with remarkable precision. By facilitating an accurate diagnosis in just a matter of minutes, our product stands as a significant advancement in the management and control of Rubella infections.

PRINCIPLE

The H. Pylori Ab Rapid Test Strip (Serum/ Plasma) is a qualitative membrane strip based immunoassay for the detection of H. Pylori antibodies in whole blood, serum or plasma. In this test procedure, the test strip is immersed in the specimen or specimen containing buffering solution. This specimen migrates chromatographically along the length of the test strip and interacts with the reagents contained on the test strip. If the specimen contains H. Pylori antibodies, a colored line will appear in the test line region indicating a positive result. If the specimen does not contain H.

Pylori antibodies, a colored line will not appear in this region indicating a negative result. To serve as a procedural control, a colored line will always appear at the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred.


Product Detail

Brand: QL

Specimens: : Serum/Plasma

Reading time:20 minutes.

Pack:25 T

STORAGE: 2‐30°C

KIT COMPONENTS(Device)

Individually packed test devices/strips 

Disposable pipettes

Buffer

Package insert

 

Brand: QL

Specimens: : Whole Blood/Serum/Plasma

Reading time:20 minutes.

Pack:25 T

STORAGE: 2‐30°C

Individually packed test devices/strips 

Disposable pipettes

Buffer

Package insert

PROCEDURE

  • Allow the test device, specimen, buffer, and/or controls to equilibrate to room temperature (15-30°C) prior to testing.
  • Remove the test device from the foil pouch and use it as soon as possible. Best results will be obtained if the assay is performed within one hour.
  • Place the test device on a clean and level surface.
  • Hold the dropper vertically and transfer 2 drops of sample to the specimen well (S) of the test device, then add 1 drop of buffer and start the timer.
  • Wait for the red line(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes.

INTERPRETATION OF RESULTS


  • POSITIVE RESULT:

    * A colored band appears in the control band region (C) and another colored band appears in the T band region. 
    NEGATIVE RESULT: 
    One colored band appears in the control band region (C). No band appears in the test band region (T). 
    INVALID RESULT: 
    Control band fails to appear. Results from any test which has not produced a control band at the specified reading time must be discarded. Please review the procedure and repeat with a new test. If the problem persists, discontinue using the kit immediately and contact your local distributor. 
    NOTE: 
    1. The intensity of the color in test region (T) may vary depending on the concentration of aimed substances present in the specimen. Therefore, any shade of color in the test region should be considered positive. Besides, the substances level can not be determined by this qualitative test. 
    2. Insufficient specimen volume, incorrect operation procedure, or performing expired tests are the most likely reasons for control band failure.




Embarking on a detailed exploration of our product, one will appreciate its inherent advantages. The ease of use and non-invasiveness are among the key features that set our test strips/devices apart. With just a simple procedure that can be performed in various settings without the need for elaborate laboratory equipment, healthcare practitioners are empowered to make informed decisions swiftly. This rapid turnaround is crucial not only in enhancing patient care but also in controlling the spread of Rubella, a disease with potentially serious implications for pregnant women and their unborn children. In essence, QL Biotech's Rubella IgG/IgM Rapid Test Strip/Device is more than just a diagnostic tool; it's a beacon of hope for millions worldwide. By providing quick, accurate, and accessible testing solutions, we are at the forefront of combating Rubella, safeguarding public health, and ensuring the well-being of future generations.