Quick & Reliable Syphilis Test at Home - QL Biotech

Short Description:

The Typhoid IgG/IgM Rapid Test Device is a lateral flow immunoassay for the simultaneous detection and differentiation of anti-Salmonella typhi (S. typhi) IgG and IgM in human whole blood, serum or plasma.


Product Detail

Product Tags

In today’s world, the importance of accessible, reliable, and discreet healthcare testing cannot be overstated. Addressing this need, QL Biotech introduces its pioneering solution for syphilis testing from the comfort of your home. The Syphilis IgG/IgM Rapid Test Device stands as a beacon of innovation in health diagnostics, offering an unparalleled blend of privacy, accuracy, and convenience. This cutting-edge testing device utilizes a lateral flow chromatographic immunoassay method, a testament to the latest advancements in medical technology. This method is not only highly efficient but also ensures the precision and reliability of your test results. The Syphilis IgG/IgM Rapid Test Device is specifically designed to detect both IgG and IgM antibodies to the syphilis-causing bacteria in the human body. This dual-detection system enhances the accuracy of the diagnosis, allowing for the early detection of the disease, which is crucial for timely treatment and management.

PRINCIPLE

The Typhoid IgG/IgM Rapid Test Device is a lateral flow chromatographic immunoassay. The test cassette consists of: 1) a burgundy colored conjugate pad containing recombinant S. typhoid H antigen and O antigen conjugated with colloid gold (Typhoid conjugates) and rabbit IgG-gold conjugates, 2) a nitrocellulose membrane strip containing two test bands (IgG and IgM bands) and a control band (C band). The IgM band is pre-coated with monoclonal anti-human IgM for the detection of IgM anti-S. typhi, IgG band is pre-coated with reagents for the detection of IgG anti-S. typhi , and the C band is pre-coated with goat anti rabbit IgG.

When an adequate volume of test specimen is dispensed into the sample well of the cassette, the test specimen migrates by capillary action across the test cassette. Anti-S. typhi IgM if present in the patient specimen will bind to the Typhoid conjugates. The immunocomplex is then captured on the membrane by the pre-coated anti-human IgM antibody, forming a burgundy colored IgM band, indicating a S. typhi IgM positive test result.

Anti-S. typhi IgG if present in the patient specimen will bind to the Typhoid conjugates. The immunocomplex is then captured by the pre-coated reagents on the membrane, forming a burgundy colored IgG band, indicating a S. typhi IgG positive test result.

Absence of any test bands suggests a negative result. The test contains an internal control (C band) which should exhibit a burgundy colored band of the immunocomplex of goat anti rabbit

IgG/rabbit IgG-gold conjugate regardless of the color development on any of the test bands.

Otherwise, the test result is invalid and the specimen must be retested with another device.


Product Detail

              • 1.Brand: QL

                Specimens: :Whole Blood/Serum/Plasma

                Reading time:10 minutes.

                Pack:25 T

                STORAGE: 2‐30°C

                KIT COMPONENTS

                • Test devices
                • Droppers
                • Buffer
                • Package insert

                 

                2.Brand: QL

                Specimens: :Serum/Plasma

                Reading time:1 minutes.

                Pack:25 T

                STORAGE: 2‐30°C

                KIT COMPONENTS

                • Test devices
                • Droppers
                • Buffer
                • Package insert

 

  • ASSAY PROCEDURE

        • 1.Typhoid IgG/IgM Rapid Test Device(Whole Blood/Serum/Plasma)Allow test device, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing. 
          1. Bring the pouch to room temperature before opening it. Remove the test device from the sealed pouch and use it as soon as possible. 
          2. Place the test device on a clean and level surface. 
          For Whole Blood, Serum or Plasma specimens: 
          Hold the dropper vertically and transfer 2 drops of specimen (or approximately 50 µL) to the specimen well (S) of the test device, then add 1 drop of buffer and start the timer. 
          For Fingerstick Whole Blood specimens: 
          To use a capillary tube: Fill the capillary tube and transfer approximately 50 µL (or 2 drops) of fingerstick whole blood specimen to the specimen well (S) of the test device, then add 1 drop of buffer and start the timer. 
          3. Wait for the colored line(s) to appear. Read results at 10 minutes. Do not interpret results after 20 minutes. 

          2 Typhoid IgG/IgM Rapid Test Device(Serum/Plasma)
          1. Bring the specimen and test components to room temperature. Open the pouch at the notch and remove device. Place the test device on a clean, flat surface. 
          2. Fill the pipette dropper with the specimen. Holding the dropper vertically, dispense 1 drop (about 40 µL) of specimen into the sample well making sure that there are no air bubbles. Then add 1 drop (about 35-50 µL) of Sample Diluent immediately. Set up timer. 
          3. Results can be read in 15 minutes. Positive results can be visible in as short as 1 minute. Don’t read result after 15 minutes.


        INTERPRETATION OF ASSAY RESULT

        Typhoid IgG/IgM

          • NOTE:

        • 1.The intensity of the color in test region (T) may vary depending on the concentration of aimed substances present in the specimen. Therefore, any shade of color in the test region should be considered positive. Besides, the substances level cannot be determined by this qualitative test.
        • 2.Insufficient specimen volume, incorrect operation procedure, or performing expired tests are the most likely reasons for control band failure.
        •  


        Understanding the principles behind the test is essential for appreciating its innovation. Upon application of the specimen, it reacts with the particle-coated, syphilis-specific antigens on the test strip. This reaction is visible as a colored line in the test region if antibodies to syphilis are present in the specimen. This process, reminiscent of a finely tuned orchestra, provides results that are both rapid and reliable. The simplicity of the procedure demystifies syphilis testing, making it an accessible option for everyone. Embark on a journey towards empowered health management with the Syphilis IgG/IgM Rapid Test Device by QL Biotech. Experience peace of mind and confidentiality as you take the first step towards proactive health monitoring from the privacy of your home.

      • Previous:
      • Next: