Rapid 4th Generation HIV Test: QL Biotech's Innovative Rotavirus Detection Tool

Short Description:

The Rotavirus Rapid Test Device (Feces) is a rapid visual immunoassay for the qualitative presumptive detection of rotavirus in human fecal specimens. This kit is intended to be used as an aid in the diagnosis of rotavirus infection. 


Product Detail

Product Tags

QL Biotech introduces its Rapid 4th Generation HIV Test, an exclusive rotavirus detection device transforming diagnostic procedures with speed and efficacy. The product, ingeniously designed, detects rotavirus infections by interpreting color variations on the internal strip, providing an uncomplicated yet efficient testing approach. Originally aimed at detecting the rotavirus, a common cause of gastroenteritis in infants and children worldwide, QL Biotech's Rapid 4th Generation HIV Test has revolutionized diagnostic procedures with its groundbreaking design and precision. The presence of rotavirus in fecal matter activates a color reaction within the device, which is visually interpreted to diagnose the infection. Understanding the significance of speedy and accurate diagnosis, our product serves as an invaluable tool in medical settings worldwide. With the capacity to provide immediate results, our Rapid 4th Generation HIV Test reduces the wait time significantly compared to other conventional diagnostic methods. The test device is designed with the intention to facilitate better healthcare decisions, by providing immediate and accurate results.

PRINCIPLE

It has been designed to detect rotavirus through visual interpretation of color development in the internal strip. The membrane was immobilized with antirotavirus antibodies on the test region. During the test, the specimen is allowed to react with colored anti-rotavirus antibodies colloidal gold conjugates, which were precoated on the sample pad of the test.

The mixture then moves on the membrane by a capillary action, and interact with reagents on the membrane. If there were enough rotavirus in specimens, a colored band will form at the T region of the membrane.


Product Detail

  • Brand: QL

    Specimens: : Feces

    Reading time:10 minutes.

    Pack:20 T

    STORAGE: 2‐30°C

    KIT COMPONENTS(Device)

    • Individually packed test devices
    • Specimens dilution tube with buffer
    • Disposable pipettes
    • Package insert

 

PROCEDURE

    • Bring tests, specimens, buffer and/or controls to room temperature (15-30°C) before use. 
      1. Specimen collection and pre-treatment: 
      1) Use the specimen collection container for specimen collection. Best results will be obtained if the assay is performed within 6 hours after collection. 
      2) For solid specimens: Unscrew and remove the dilution tube applicator. Be careful not to spill or spatter solution from the tube. Collect specimens by inserting the applicator stick into at least 3 different sites of the feces to collect approximately 50 mg of feces (equivalent to 1/4 of a pea). 
      For liquid specimens: Hold the pipette vertically, aspirate fecal specimens, and then transfer 2 drops (approximately 50 µL) into the specimen collection tube containing the extraction buffer. 
      3) Place the applicator back into the tube and screw the cap tightly. Be careful not to break the tip of the dilution tube. 
      4) Shake the specimen collection tube vigorously to mix the specimen and the extraction buffer. Specimens prepared in the specimen collection tube may be stored for 6 months at -20°C if not tested within 1 hour after preparation. 
      2. Testing 
      1) Remove the test from its sealed pouch, and place it on a clean, level surface. Label the test with patient or control identification. To obtain a best result, the assay should be performed within one hour. 
      2) Using a piece of tissue paper, break the tip of the dilution tube. Hold the tube vertically and dispense 3 drops of solution into the specimen well (S) of the test device. 
      Avoid trapping air bubbles in the specimen well (S), and do not drop any solution in observation window. 
      As the test begins to work, you will see color move across the membrane. 
      3. Wait for the colored band to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes. 
      Note: If the specimen does not migrate (presence of particles), centrifuge the extracted specimens contained in the extraction buffer vial. Collect 80 µL of supernatant, dispense into the specimen well (S) of a new test device and start afresh following the instructions mentioned above.

    KIT COMPONENTS(Device)



    Individually packed test devices
    Each device contains a strip with colored conjugates and reactive reagents pre-spreaded at the corresponding regions.
    Specimens dilution tube with
    buffer
    0.1 M Phosphate buffered saline (PBS) and preservative
    Disposable pipettes
    For watery specimens collection use.
    Package insert
    For operation instruction.
    NOTE:
    The intensity of the color in test region (T) may vary depending on the concentration of aimed substances present in the specimen. Therefore, any shade of color in the test region should be considered positive. Besides, the substances level can not be determined by this qualitative test.
    Insufficient specimen volume, incorrect operation procedure, or performing expired tests are the most likely reasons for control band failure.
     


    A salient feature of the Rapid 4th Generation HIV Test is its user-friendly design, requiring no extensive training or specialized skills to operate. The simplicity of the device does not compromise its integrity or precision, making it a dependable tool in rotavirus detection. With the 4th Generation HIV Test, we ensure a reliable, fast, and accessible solution to healthcare professionals, making a tangible difference in patient care and recovery. In the ever-evolving healthcare landscape, our Rapid 4th Generation HIV Test stands as a testament to QL Biotech's commitment to innovation and accuracy. By marrying cutting-edge technology with the universal need for reliable healthcare, we have developed a product that truly makes a difference. The 4th Generation HIV Test, a detector of rotavirus, exemplifies our dedication to improving global health through advanced diagnostic tools. Invest in innovation, invest in accuracy - choose QL Biotech's Rapid 4th Generation HIV Test.

  • Previous:
  • Next: