Reliable H.Pylori Antigen Rapid Test Kits | QL Biotech

Short Description:

The HCV Rapid Test Device (Whole Blood /Serum/Plasma) is a rapid visual immunoassay for the qualitative presumptive detection of antibodies to HCV in human whole blood, serum or plasma specimens. This kit is intended to be used as an aid in the diagnosis of HCV infection.


Product Detail

Product Tags

QL Biotech proudly presents the H.Pylori Antigen Rapid Test Device, a pioneering solution designed for the swift and reliable identification of the H.Pylori antigen from Whole Blood, Serum, or Plasma samples. This innovative device underscores our commitment to advancing healthcare diagnostics, offering individuals and healthcare professionals a convenient, yet highly accurate means of managing gastrointestinal health. Understanding the critical role that timely detection plays in the effective management of H.Pylori-related conditions, our H.Pylori Antigen Rapid Test Device stands out as a hallmark of precision and dependability. Utilizing advanced immunochromatographic techniques, the test harnesses the principle of antigen-antibody reaction, coupled with color development, to deliver results that are both visually interpretable and scientifically robust.

PRINCIPLE

The HCV Rapid Test Device (Whole Blood /Serum/Plasma) has been designed to detect antibodies to HCV through visual interpretation of color development in the internal strip. The membrane was immobilized with protein A on the test region. During the test, the specimen is allowed to react with colored recombinant HCV antigens colloidal gold conjugates, which were precoated on the sample pad of the test. The mixture then moves on the membrane by a capillary action, and interacts with reagents on the membrane. If there were enough HCV antibodies in specimens, a colored band will from at the test region of the membrane. Presence of this colored band indicates a positive result, while its absence indicates a negative result. Appearance of a colored band at the control region serves as a procedural control. This indicates that proper volume of specimen has been added and membrane wicking has occurred.


Product Detail

Brand: QL

Specimens: : Whole Blood/Serum/Plasma

Reading time:10 minutes.

Pack:25 T

STORAGE: 2‐30°C

KIT COMPONENTS:

Individually packed test strips

Disposable pipettes

Buffer

Package insert

 

PROCEDURE

    • Bring tests, specimens, buffer and/or controls to room temperature (15-30°C) before use. 
      1. Remove the test from its sealed pouch, and place it on a clean, level surface. Label the device with patient or control identification. To obtain a best result, the assay should be performed within one hour. 
      2. For Serum or Plasma specimen: Hold the dropper vertically and transfer 2 drops of serum or plasma (approximately 50l ) and 1 drop buffer to the specimen well (S) of the test device, and start the timer. 
      For Venipuncture Whole Blood specimen: Hold the dropper vertically and transfer 2 drops of 
      venipuncture whole blood (approximately 50 l) to the specimen well (S) of the test device, then add 2 dropsof buffer and startthe timer. 
      For FingerstickWhole Bloodspecimen: 
      To use a capillary tube: Fill the capillary tube and transfer approximately 50l of fingerstick whole blood specimen to the specimen well (S) of the test device, then add 2 drops of buffer 
      and startthetimer. 
      To use hanging drop: Allow 2 hanging drop of fingerstick whole blood specimen (approximately 50l ) to fall into the center of the specimen well (S) on the test device, then add 2 dropsof buffer and startthe timer. 
      3. Wait for the red line(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes.

    INTERPRETATION OF RESULTS


    • POSITIVERESULT: 
      * A colored band appears in the control band region (C) and another colored band appears in the T band region. 
      NEGATIVERESULT: 
      One colored band appears in the control band region (C). No band appears in the test band region (T).
      INVALID RESULT: 
      Control band fails to appear. Results from any test which has not produced a control band at the specified reading time must be discarded. Please review the procedure and repeat with a new test. 
      If the problem persists, discontinue using the kit immediately and contact your local distributor. 
      NOTE: 
      1. The intensity of the color in test region (T) may vary depending on the concentration of aimed substances present in the specimen. Therefore, any shade of color in the test region should be considered positive. Besides, the substances level can not be determined by this qualitative test. 
      2. Insufficient specimen volume, incorrect operation procedure, or performing expired tests are the most likely reasons for control band failure.




    When it comes to diagnosing the presence of the H.Pylori bacterium - a known causative agent of various gastrointestinal disorders such as peptic ulcers and chronic gastritis - accuracy and speed are paramount. Our device is meticulously designed to meet these needs, simplifying the testing process without compromising on quality. With just a small sample of Whole Blood, Serum, or Plasma, the test yields results within minutes, thus facilitating early intervention and tailored treatment plans. This not only enhances patient care but also significantly contributes to better health outcomes. QL Biotech is committed to empowering healthcare professionals and patients with tools that make a difference. The H.Pylori Antigen Rapid Test Device is a testament to this, embodying our mission to innovate for health and wellbeing.