Revolutionary HCV Rapid Test: Detection of Feline Infectious Peritonitis Antibody Made Easy

Short Description:

The HCV Rapid Test Device (Whole Blood /Serum/Plasma) is a rapid visual immunoassay for the qualitative presumptive detection of antibodies to HCV in human whole blood, serum or plasma specimens. This kit is intended to be used as an aid in the diagnosis of HCV infection.


Product Detail

Product Tags

QL Biotech proudly presents our advanced HCV Rapid Test Device, designed to revolutionize the process of detecting antibodies to Hepatitis C Virus (HCV). What sets our innovative device apart is its ingenious capability to also aid in the detection of feline infectious peritonitis antibody, adding a vital layer of functionality to the product. The HCV Rapid Test Device is carefully engineered for an uncomplicated testing procedure involving whole blood, serum, or plasma. The technology works powerfully to detect the presence of HCV antibodies, delivering results through the visual interpretation of color development intrinsic to the internal strip. This visual aid ensures a quick, user-friendly, and accurate reading of results, helping to speed up the diagnosis process and enable immediate intervention if necessary.

PRINCIPLE

The HCV Rapid Test Device (Whole Blood /Serum/Plasma) has been designed to detect antibodies to HCV through visual interpretation of color development in the internal strip. The membrane was immobilized with protein A on the test region. During the test, the specimen is allowed to react with colored recombinant HCV antigens colloidal gold conjugates, which were precoated on the sample pad of the test. The mixture then moves on the membrane by a capillary action, and interacts with reagents on the membrane. If there were enough HCV antibodies in specimens, a colored band will from at the test region of the membrane. Presence of this colored band indicates a positive result, while its absence indicates a negative result. Appearance of a colored band at the control region serves as a procedural control. This indicates that proper volume of specimen has been added and membrane wicking has occurred.


Product Detail

Brand: QL

Specimens: : Whole Blood/Serum/Plasma

Reading time:10 minutes.

Pack:25 T

STORAGE: 2‐30°C

KIT COMPONENTS:

Individually packed test strips

Disposable pipettes

Buffer

Package insert

 

PROCEDURE

    • Bring tests, specimens, buffer and/or controls to room temperature (15-30°C) before use. 
      1. Remove the test from its sealed pouch, and place it on a clean, level surface. Label the device with patient or control identification. To obtain a best result, the assay should be performed within one hour. 
      2. For Serum or Plasma specimen: Hold the dropper vertically and transfer 2 drops of serum or plasma (approximately 50l ) and 1 drop buffer to the specimen well (S) of the test device, and start the timer. 
      For Venipuncture Whole Blood specimen: Hold the dropper vertically and transfer 2 drops of 
      venipuncture whole blood (approximately 50 l) to the specimen well (S) of the test device, then add 2 dropsof buffer and startthe timer. 
      For FingerstickWhole Bloodspecimen: 
      To use a capillary tube: Fill the capillary tube and transfer approximately 50l of fingerstick whole blood specimen to the specimen well (S) of the test device, then add 2 drops of buffer 
      and startthetimer. 
      To use hanging drop: Allow 2 hanging drop of fingerstick whole blood specimen (approximately 50l ) to fall into the center of the specimen well (S) on the test device, then add 2 dropsof buffer and startthe timer. 
      3. Wait for the red line(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes.

    INTERPRETATION OF RESULTS


    • POSITIVERESULT: 
      * A colored band appears in the control band region (C) and another colored band appears in the T band region. 
      NEGATIVERESULT: 
      One colored band appears in the control band region (C). No band appears in the test band region (T).
      INVALID RESULT: 
      Control band fails to appear. Results from any test which has not produced a control band at the specified reading time must be discarded. Please review the procedure and repeat with a new test. 
      If the problem persists, discontinue using the kit immediately and contact your local distributor. 
      NOTE: 
      1. The intensity of the color in test region (T) may vary depending on the concentration of aimed substances present in the specimen. Therefore, any shade of color in the test region should be considered positive. Besides, the substances level can not be determined by this qualitative test. 
      2. Insufficient specimen volume, incorrect operation procedure, or performing expired tests are the most likely reasons for control band failure.




    Beyond its primary function, our HCV Rapid Test Device excels in facilitating the detection of feline infectious peritonitis antibody. This is an essential tool for veterinarians and pet owners who seek to ensure the health and well-being of their feline companions. Feline infectious peritonitis, a deadly disease caused by a mutation of the feline enteric coronavirus, can be challenging to diagnose due to the similarity of its symptoms to other ailments. But with our HCV Rapid Test Device, detection of the feline infectious peritonitis antibody becomes simplified, saving precious time and resources for effective treatment planning. QL Biotech's commitment to providing scientifically-sound, accurate, and effective testing solutions remains unwavering. Whether it's for human health or the well-being of our beloved pets, we innovate and engineer products that truly make a difference. Trust QL Biotech to provide professional-grade HCV Rapid Test Devices designed to excel in the detection of both HCV antibodies and feline infectious peritonitis antibodies.

  • Previous:
  • Next: