Swift and Accurate Tuberculosis Detection with Rapid Test Kit

Short Description:

The TB IgG/IgM Rapid Test Device (Whole Blood/Serum/Plasma) is a sandwich lateral flow chromatographic immunoassay for the qualitative detection of antibodies (IgG and IgM) anti-Mycobacterium Tuberculosis (M.TB) in human serum or plasma. It is intended to be used as a screening test and as an aid in the diagnosis of infection with M. TB. Any reactive specimen with the TB IgG/ IgM Rapid Test device must be confirmed with alternative testing method(s) and clinical findings.


Product Detail

Product Tags

At QL Biotech, we present a groundbreaking Tuberculosis Rapid Test Device that offers swift detection of Tuberculosis. Our device utilizes a lateral flow chromatographic immunoassay, a technology developed in line with the double antigen-sandwich technique principle. This technique enhances the test's accuracy, ensuring reliable results every time. Our Rapid Test Device is versatile and efficient, making it ideal for various testing needs including Chlamydia Rapid Test, Gonorrhea Test, H.Pylori Test, Malaria Rapid Test, Rota Virus Test, Adeno Test, Strep A Rapid Test, and Syphilis Test. In addition to these, it is well-suited for communicable disease tests such as the Dengue Rapid Test and HIV Rapid Test, among others. It is further compatible for Hepatitis tests, including Hbsag Hepatitis B Rapid Test and HCV Rapid Test, as well as for other diseases like Typhoid, HSV, and RSV.

PRINCIPLE

The TB Antibody Rapid Test device is a lateral flow chromatographic immunoassay based on the principle of the double antigen–sandwich technique. The test cassette consists of: 1) a burgundy colored conjugate pad containing M.TB antigens conjugated with colloid gold (M.TB conjugates)and rabbit IgG‐gold conjugates, 2) a nitrocellulose membrane strip containing a test band (T band) and a control band (C band). The T band is pre‐coated with non‐conjugated M.TB antigens, and the C band is pre‐coated with goat anti‐rabbit IgG. When an adequate volume of test specimen is dispensed into the sample well of the cassette, the specimen migrates by capillary action across the cassette. The antibodies: either the IgG, the IgM to M. TB if present in the specimen will bind to the M.TB conjugates. The immunocomplex is then captured on the membrane by the pre‐coated M.TB antigens, forming a burgundy colored T band, indicating a M.TB Ab positive test result. Absence of the T band suggests a negative result. The test contains an internal control (C band) which should exhibit a burgundy colored band of the immunocomplex of goat anti‐rabbit IgG/rabbit IgG‐gold conjugate regardless the presence of any antibodies to M.TB. Otherwise, the test result is invalid and the specimen must be retested with another device.


Product Detail

          • Brand: QL

            Specimens: :Plasma/ Serum/ Whole Blood

            Reading time:1 minutes.

            Pack:25 T

            STORAGE: 2‐30°C

            KIT COMPONENTS

            • Test devices
            • Droppers
            • Buffer
            • Package insert

 

  • TEST PRINCIPLE

        • The TB IgG/IgM Rapid Test Device (Whole Blood/Serum/Plasma) is a lateral flow chromatographic immunoassay based on the principle of the double antigen–sandwich technique. The test cassette consists of: 1) a burgundy colored conjugate pad containing M.TB antigens conjugated with colloid gold (M.TB conjugates) and rabbit IgG‐gold conjugates, 2) a nitrocellulose membrane strip containing a test band (T band) and a control band (C band). The T band is pre‐coated with non‐conjugated M.TB antigens, and the C band is pre‐coated with goat anti‐rabbit IgG.

          When an adequate volume of test specimen is dispensed into the sample well of the cassette, the specimen migrates by capillary action across the cassette. The antibodies: either the IgG, the IgM to M. TB if present in the specimen will bind to the M.TB conjugates. The immunocomplex is then captured on the membrane by the pre‐coated M.TB antigens, forming a burgundy colored T band, indicating a M.TB Ab positive test result.

          Absence of the T band suggests a negative result. The test contains an internal control (C band) which should exhibit a burgundy colored band of the immunocomplex of goat anti‐rabbit IgG/rabbit IgG‐gold conjugate regardless the presence of any antibodies to M.TB. Otherwise, the test result is invalid and the specimen must be retested with another device.


        ASSAY PROCEDURE

        1. Bring the specimen and test components to room temperature. Place the test device  on a clean, flat surface. 
        2. Be sure to label the device with specimen’s ID number. 
        3. Fill the plastic dropper with the specimen. Holding the dropper vertically, dispense 2  drops (about 80 µL) of specimen into the sample well making sure that there are no  air bubbles. Then add 1 drop of buffer into the sample well. Set up timer. 
        4. Results can be read in 10 minutes. Positive results can be visible in as short as 1  minute. Don’t read result after 10 minutes. To avoid confusion, discard the test  device after interpreting the result.

        •  
        • INTERPRETATION OF ASSAY RESULT



          IgG Positive:* The colored line in the control line region (C) appears and a colored line appears in test line region IgG. The result is positive for Tuberculosis specific-IgG antibodies and is indicative of secondary Tuberculosis infection.

          IgM Positive:* The colored line in the control line region (C) appears and a colored line appears in test line region IgM. The result is positive for Tuberculosis specific-IgM and is probably indicative of primary Tuberculosis infection.

          IgG and IgM Positive:* The colored line in the control line region (C) appears and two colored lines should appear in test line regions IgG and IgM. The color intensities of the lines do not have to match. The result is positive for IgG & IgM antibodies and is indicative of secondary Tuberculosis infection.

          *NOTE: The intensity of the color in the test line region(s) will vary depending on the concentration of Tuberculosis antibodies in the specimen. Therefore, any shade of color in the test line region(s) should be considered positive.

          NEGATIVE RESULT:

          The colored line in the control line region (C) appears. No line appears in test line regions IgG or IgM.

          INVALID RESULT:

          Control line (C) falls to appear. Insufficient buffer volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the procedure with a new test device. If the problem persists, discontinue using the test kit immediately and contact your local distributor.
           



        The kit’s design enables easy operating for both professionals and individuals wanting to test at home, with clear instructions provided. The compact and portable nature of the test kit makes it suitable for both in-clinic and at-home use. The consistency and speed of results make it a preferred choice for health professionals worldwide. Trust in QL Biotech's commitment to delivering top-notch, rapid, and reliable diagnostic solutions. We meticulously engineer our products to ensure that health professionals are equipped with the necessary tools to diagnose and combat infectious diseases. With our Tuberculosis Rapid Test Device, early detection and immediate treatment become feasible—a critical step in containing the spread of diseases. Achieve fast, accurate, and reliable results with QL Biotech.

      • Previous:
      • Next: