Unsurpassed Accuracy of QL Biotech's Rapid 4th Generation HIV Test Device

Short Description:

The Typhoid IgG/IgM Rapid Test Device is a lateral flow immunoassay for the simultaneous detection and differentiation of anti-Salmonella typhi (S. typhi) IgG and IgM in human whole blood, serum or plasma.


Product Detail

Product Tags

QL Biotech, a leader in the biotechnology industry, proudly introduces the Typhoid IgG/IgM Rapid Test Device, now reimagined as the Rapid 4th Generation HIV Test. Excelling in innovation and reliability, this device pushes the boundaries of quick and high-quality health diagnostics. Working on the principles of lateral flow chromatographic immunoassay, the Rapid 4th Generation HIV Test provides accurate and efficient detection of both HIV antigens and antibodies. This ensures not only the detection of an active infection but also provides insight into past exposure, offering a comprehensive overview of the patient's HIV status.

PRINCIPLE

The Typhoid IgG/IgM Rapid Test Device is a lateral flow chromatographic immunoassay. The test cassette consists of: 1) a burgundy colored conjugate pad containing recombinant S. typhoid H antigen and O antigen conjugated with colloid gold (Typhoid conjugates) and rabbit IgG-gold conjugates, 2) a nitrocellulose membrane strip containing two test bands (IgG and IgM bands) and a control band (C band). The IgM band is pre-coated with monoclonal anti-human IgM for the detection of IgM anti-S. typhi, IgG band is pre-coated with reagents for the detection of IgG anti-S. typhi , and the C band is pre-coated with goat anti rabbit IgG.

When an adequate volume of test specimen is dispensed into the sample well of the cassette, the test specimen migrates by capillary action across the test cassette. Anti-S. typhi IgM if present in the patient specimen will bind to the Typhoid conjugates. The immunocomplex is then captured on the membrane by the pre-coated anti-human IgM antibody, forming a burgundy colored IgM band, indicating a S. typhi IgM positive test result.

Anti-S. typhi IgG if present in the patient specimen will bind to the Typhoid conjugates. The immunocomplex is then captured by the pre-coated reagents on the membrane, forming a burgundy colored IgG band, indicating a S. typhi IgG positive test result.

Absence of any test bands suggests a negative result. The test contains an internal control (C band) which should exhibit a burgundy colored band of the immunocomplex of goat anti rabbit

IgG/rabbit IgG-gold conjugate regardless of the color development on any of the test bands.

Otherwise, the test result is invalid and the specimen must be retested with another device.


Product Detail

              • 1.Brand: QL

                Specimens: :Whole Blood/Serum/Plasma

                Reading time:10 minutes.

                Pack:25 T

                STORAGE: 2‐30°C

                KIT COMPONENTS

                • Test devices
                • Droppers
                • Buffer
                • Package insert

                 

                2.Brand: QL

                Specimens: :Serum/Plasma

                Reading time:1 minutes.

                Pack:25 T

                STORAGE: 2‐30°C

                KIT COMPONENTS

                • Test devices
                • Droppers
                • Buffer
                • Package insert

 

  • ASSAY PROCEDURE

        • 1.Typhoid IgG/IgM Rapid Test Device(Whole Blood/Serum/Plasma)Allow test device, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing. 
          1. Bring the pouch to room temperature before opening it. Remove the test device from the sealed pouch and use it as soon as possible. 
          2. Place the test device on a clean and level surface. 
          For Whole Blood, Serum or Plasma specimens: 
          Hold the dropper vertically and transfer 2 drops of specimen (or approximately 50 µL) to the specimen well (S) of the test device, then add 1 drop of buffer and start the timer. 
          For Fingerstick Whole Blood specimens: 
          To use a capillary tube: Fill the capillary tube and transfer approximately 50 µL (or 2 drops) of fingerstick whole blood specimen to the specimen well (S) of the test device, then add 1 drop of buffer and start the timer. 
          3. Wait for the colored line(s) to appear. Read results at 10 minutes. Do not interpret results after 20 minutes. 

          2 Typhoid IgG/IgM Rapid Test Device(Serum/Plasma)
          1. Bring the specimen and test components to room temperature. Open the pouch at the notch and remove device. Place the test device on a clean, flat surface. 
          2. Fill the pipette dropper with the specimen. Holding the dropper vertically, dispense 1 drop (about 40 µL) of specimen into the sample well making sure that there are no air bubbles. Then add 1 drop (about 35-50 µL) of Sample Diluent immediately. Set up timer. 
          3. Results can be read in 15 minutes. Positive results can be visible in as short as 1 minute. Don’t read result after 15 minutes.


        INTERPRETATION OF ASSAY RESULT

        Typhoid IgG/IgM

          • NOTE:

        • 1.The intensity of the color in test region (T) may vary depending on the concentration of aimed substances present in the specimen. Therefore, any shade of color in the test region should be considered positive. Besides, the substances level cannot be determined by this qualitative test.
        • 2.Insufficient specimen volume, incorrect operation procedure, or performing expired tests are the most likely reasons for control band failure.
        •  


        The device's enhanced design and updated technology make it simple to use, making it suitable for a wide range of clinical settings. Its compact size does not compromise its sophistication, allowing for swift, precision-based detection at all times. The pride and joy of QL Biotech’s extensive product line, the Rapid 4th Generation HIV Test redefines rapid diagnostics, providing reliable results when it matters most. The Rapid 4th Generation HIV Test continues QL Biotech's mission to deliver cutting-edge health solutions. Ensuring a prompt and accurate result, this device reaffirms our commitment to exceptional quality and unparalleled accuracy. Trust in the power of the Rapid 4th Generation HIV Test and choose QL Biotech for all your diagnostic needs. Explore the potential of this innovative product and experience the certainty it provides.