Introducing our Strep A Detection Test Device or Strip, a pivotal medical tool specifically engineered to enable rapid and qualitative detection of the Strep A carbohydrate antigen from a throat swab. This instrument is developed around the Chikungunya IgG and IgM Rapid Test technology, offering an effective immunoassay test system for health professionals. The primary function of this device is to facilitate a lateral flow immunoassay, a prevalent immunological method used for the quick detection and identification of the Strep A carbohydrate antigen. The use of this device empowers medical professionals to administer a proactive response in diagnosing the presence of Chikungunya IgG and IgM. Our test device/strip stands out from conventional testing methods due to its quick and easy detection process. This product aims to ensure accuracy and efficiency in every test performed. Further, it predominantly utilizes the power and accuracy of the Chikungunya IgG and IgM Rapid Test, providing credible results to the end-user.

PRINCIPLE

The Strep A Rapid Test Device/strip is a qualitative, lateral flow immunoassay for the detection of Strep A carbohydrate antigen in a throat swab. In this test, antibody specific to Strep A carbohydrate antigen is coated on the test line region of the test. During testing, the extracted throat swab specimen reacts with an antibody to Strep A that is coated onto particles. The mixture migrates up the membrane to react with the antibody to Strep A on the membrane and generate a color line in the test line region. The presence of this color line in the test line region indicates a positive result, while its absence indicates a negative result. To serve as a procedural control, a colored line will always appear in the control line region, indicating that proper volume of specimen has been added and membrane wicking has occurred.


Product Detail

    • Brand:QL

      Specimens: : Swab

      Reading time:5 minutes.

      Pack:20 T

      STORAGE: 2‐30°C

      KIT COMPONENTS(Device)

      •  •Test devices                            •Sterile swabs
      •  •Workstation                         • Strep A Reagent A (1M Sodium Nitrite )
      •  •Strep A Reagent B (0.4M Acetic Acid)      • Test tubes
      •  •Dropper tips                          • Package insert

       

      KIT COMPONENTS(strip)

      •  •Test strips                           • Sterile swabs
      •  •Workstation                          • Strep A Reagent A (1M Sodium Nitrite )
      •  •Strep A Reagent B (0.4M Acetic Acid)   • Test tubes
      •  •Package insert

 

PROCEDURE

    • Allow the test device, reagents, throat swab specimen, and/or controls to reach room temperature (15-30°C) prior to testing. 
      1. Remove the test device from the sealed foil pouch and use it as soon as possible. 
      Best results will be obtained if the test is performed immediately after opening the foil pouch. 
      2. Hold the Reagent A bottle vertically and add 4 full drops (approximately 240 µL) of Reagent A to an extraction test tube. Reagent A is red in color. Hold the 
      Reagent B bottle vertically and add 4 full drops (approximately 160 µL) to the tube. Reagent B is colorless. Mix the solution by gently swirling the extraction test tube. The addition of Reagent B to Reagent A changes the color of the solution from red to yellow. 
      3. Immediately add the throat swab to the extraction test tube of yellow solution. Agitate the swab 10 times in the tube. Leave the swab in the tube for 1 minute. Then press the swab against the side of the tube and squeeze the bottom of the tube as the swab is withdrawn. Discard the swab. 
      4. Fit the dropper tip on top of the extraction test tube. Place the test device on a clean and level surface. Add 3 full drops of solution (approx. 100 µL) to the specimen well (S) and then start the timer. 
      5. Wait for the colored line(s) to appear. Read the result at 5 minutes. Do not read the result after 10 minutes.

    INTERPRETATION OF RESULTS


    • NOTE:
    • The intensity of the color in test region (T) may vary depending on the concentration of aimed substances present in the specimen. Therefore, any shade of color in the test region should be considered positive. Besides, the substances level can not be determined by this qualitative test.
    • Insufficient specimen volume, incorrect operation procedure, or performing expired tests are the most likely reasons for control band failure.

     



    Incorporated into the product's design are quality materials and the latest technological advancements to provide a device that is not only effective but also user-friendly. The Strep A Detection Test Device/Strip is a testament to QL Biotech's commitment to innovative solutions and integral care beyond the norm. In conclusion, with an ever-increasing demand for accurate and rapid detection of the Strep A carbohydrate antigen, our Strep A Detection Test Device/Strip is a solution that amalgamates convenience, speed, and reliability. Powered by the Chikungunya IgG and IgM Rapid Test technology, this device is aiding medical practitioners globally in diagnosing and combatting the challenges presented by Strep A and Chikungunya. Trust QL Biotech for assured quality, accuracy, and efficiency in rapid medical testing solutions.