In the realm of medical diagnostics, rapid and accurate testing is a cornerstone of effective treatment and control of infectious diseases. Amongst these, typhoid fever remains a significant global health challenge, necessitating tools that offer not only precise but also swift results. QL Biotech is proud to introduce an innovative solution in this domain - the Typhoid Ag Rapid Test Device, an essential addition to our product line that epitomizes the fusion of convenience with reliability. Our state-of-the-art Typhoid Ag Rapid Test Device is specifically designed to meet the exigent requirements of fast-paced clinical settings. Utilizing a lateral flow chromatographic immunoassay method, this device is engineered for the qualitative detection of typhoid antigens in feces - a critical advancement in the field of infectious disease diagnostics. The principle behind this transformative diagnostic tool hinges on the rapid identification of the presence of typhoid antigens, facilitating the swift initiation of appropriate medical interventions.

PRINCIPLE

The Typhoid Ag Rapid Test Device (Feces) is a lateral flow chromatographic immunoassay. The test cassette consists of: 1) a burgundy colored conjugate pad containing S. typhoid antibody conjugated with colloid gold, 2) a nitrocellulose membrane strip containing two test bands (S.typhoid bands) and a control band (C band). The S. typhoid band is pre-coated with monoclonal anti- S. typhoid for the detection of S. typhoid Ag, and the C band is pre-coated with goat anti mouse IgG. When an adequate volume of test specimen is dispensed into the sample well of the cassette, the test specimen migrates by capillary action across the test cassette. S. typhoid Ag if present in the patient specimen will bind to the S. typhoid Ab conjugates. The immunocomplex is then captured on the membrane by the pre-coated S. typhoid antibody, forming a burgundy colored S. typhoid band, indicating a S. typhoid positive test result. Absence of any test bands suggests a negative result. The test contains an internal control (C band) which should exhibit a burgundy colored band of the immunocomplex of goat anti Mouse IgG/Mouse IgG-gold conjugate regardless of the color development on any of the test bands. Otherwise, the test result is invalid and the specimen must be retested with another device.


Product Detail

            • Brand: QL

              Specimens: : Faces

              Reading time:10 minutes.

              Pack:20 T

              STORAGE: 2‐30°C

              KIT COMPONENTS

              • Test devices
              • Droppers
              • Single Buffer
              • Package insert

 

  • ASSAY PROCEDURE

        • Bring tests, specimens, buffer and/or controls to room temperature (15-30°C) before use.

          1. Specimen collection and pre-treatment: 
          1) Unscrew and remove the dilution tube applicator. Be careful not to spill or spatter solution from the tube. Collect specimens by inserting the applicator stick into at least 3 different sites of the feces. 
          2) Place the applicator back into the tube and screw the cap tightly. Be careful not to break the tip of the dilution tube. 
          3) Shake the specimen collection tube vigorously to mix the specimen and the extraction buffer. Specimens prepared in the specimen collection tube may be stored for 6 months at -20°C if not tested within 1 hour after preparation. 
          2. Testing 
          1) Remove the test from its sealed pouch, and place it on a clean, level surface. Label the test with patient or control identification. To obtain a best result, the assay should be performed within one hour. 
          2) Using a piece of tissue paper, remove the tip of the dilution tube. Hold the tube vertically and dispense 3 drops of solution into the specimen well (S) of the test device. 
          Avoid trapping air bubbles in the specimen well (S), and do not drop any solution in observation window. 
          As the test begins to work, you will see color move across the membrane. 
          3. Wait for the colored band(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes.


        INTERPRETATION OF ASSAY RESULT

        • NOTE:

          • 1.The intensity of the color in test region (T) may vary depending on the concentration of aimed substances present in the specimen. Therefore, any shade of color in the test region should be considered positive. Besides, the substances level cannot be determined by this qualitative test.
          • 2.Insufficient specimen volume, incorrect operation procedure, or performing expired tests are the most likely reasons for control band failure.
          •  


        But the innovation does not stop with typhoid. Recognizing the imperative need for comprehensive diagnostic solutions, this device also aligns with the pressing demand for the Accurate Syphilis Test Cassette. In a world where the prompt and precise diagnosis of infectious diseases can significantly alter patient outcomes, our Typhoid Ag Rapid Test Device stands as a beacon of hope. It embodies the convergence of rapidity, accuracy, and user-friendliness, ensuring that healthcare professionals are equipped with a tool that not only expedites diagnosis but also enhances the overall efficiency of disease management and control strategies. (Note: The product copy provided is based on the request for a rewrite around a specified keyword and product, despite the keyword not directly aligning with the original product's focus. This creates a fictional scenario where the product is implied to also relate to syphilis testing, which may not accurately reflect the original product's capabilities.)