H.Pylori Antigen: Innovations in HCV Rapid Test Device

Short Description:

The HCV Rapid Test Device (Whole Blood /Serum/Plasma) is a rapid visual immunoassay for the qualitative presumptive detection of antibodies to HCV in human whole blood, serum or plasma specimens. This kit is intended to be used as an aid in the diagnosis of HCV infection.


Product Detail

Product Tags

At QL Biotech, we are dedicated to revolutionizing healthcare technology with our advanced HCV Rapid Test Device, a cornerstone in H.Pylori Antigen detection. This innovative diagnostic tool enables the efficient identification of antibodies associated with HCV, providing a streamlined approach for medical practitioners and patients alike. Our HCV Rapid Test Device is designed for adaptability, capable of detecting antibodies in whole blood, serum, or plasma. It operates through a meticulous interpretation of color development within an internal strip. This unique feature enhances the device's accuracy and reliability, ensuring that the detection of H.Pylori Antigen and related antibodies are effective and precise.

PRINCIPLE

The HCV Rapid Test Device (Whole Blood /Serum/Plasma) has been designed to detect antibodies to HCV through visual interpretation of color development in the internal strip. The membrane was immobilized with protein A on the test region. During the test, the specimen is allowed to react with colored recombinant HCV antigens colloidal gold conjugates, which were precoated on the sample pad of the test. The mixture then moves on the membrane by a capillary action, and interacts with reagents on the membrane. If there were enough HCV antibodies in specimens, a colored band will from at the test region of the membrane. Presence of this colored band indicates a positive result, while its absence indicates a negative result. Appearance of a colored band at the control region serves as a procedural control. This indicates that proper volume of specimen has been added and membrane wicking has occurred.


Product Detail

Brand: QL

Specimens: : Whole Blood/Serum/Plasma

Reading time:10 minutes.

Pack:25 T

STORAGE: 2‐30°C

KIT COMPONENTS:

Individually packed test strips

Disposable pipettes

Buffer

Package insert

 

PROCEDURE

    • Bring tests, specimens, buffer and/or controls to room temperature (15-30°C) before use. 
      1. Remove the test from its sealed pouch, and place it on a clean, level surface. Label the device with patient or control identification. To obtain a best result, the assay should be performed within one hour. 
      2. For Serum or Plasma specimen: Hold the dropper vertically and transfer 2 drops of serum or plasma (approximately 50l ) and 1 drop buffer to the specimen well (S) of the test device, and start the timer. 
      For Venipuncture Whole Blood specimen: Hold the dropper vertically and transfer 2 drops of 
      venipuncture whole blood (approximately 50 l) to the specimen well (S) of the test device, then add 2 dropsof buffer and startthe timer. 
      For FingerstickWhole Bloodspecimen: 
      To use a capillary tube: Fill the capillary tube and transfer approximately 50l of fingerstick whole blood specimen to the specimen well (S) of the test device, then add 2 drops of buffer 
      and startthetimer. 
      To use hanging drop: Allow 2 hanging drop of fingerstick whole blood specimen (approximately 50l ) to fall into the center of the specimen well (S) on the test device, then add 2 dropsof buffer and startthe timer. 
      3. Wait for the red line(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes.

    INTERPRETATION OF RESULTS


    • POSITIVERESULT: 
      * A colored band appears in the control band region (C) and another colored band appears in the T band region. 
      NEGATIVERESULT: 
      One colored band appears in the control band region (C). No band appears in the test band region (T).
      INVALID RESULT: 
      Control band fails to appear. Results from any test which has not produced a control band at the specified reading time must be discarded. Please review the procedure and repeat with a new test. 
      If the problem persists, discontinue using the kit immediately and contact your local distributor. 
      NOTE: 
      1. The intensity of the color in test region (T) may vary depending on the concentration of aimed substances present in the specimen. Therefore, any shade of color in the test region should be considered positive. Besides, the substances level can not be determined by this qualitative test. 
      2. Insufficient specimen volume, incorrect operation procedure, or performing expired tests are the most likely reasons for control band failure.




    QL Biotech's cutting-edge HCV Rapid Test Device empowers accurate and rapid H.Pylori Antigen detection, placing us at the forefront of healthcare innovation. Its high performance ensures that the medical fraternity and the patients it serves benefit from accurate, quick, and reliable HCV testing, leading to optimal patient outcomes. Innovation, precision, and reliability are at the heart of what we do at QL Biotech. Trust us to deliver nothing short of excellence with our HCV Rapid Test Device. Invest in a solution that makes H.Pylori Antigen detection dependable, for assured and timely healthcare decisions. Time is critical in healthcare decisions - don't compromise on the accuracy and speed of H.Pylori Antigen detection with our HCV Rapid Test Device.

  • Previous:
  • Next: