QL Biotech proudly introduces the Hbsag Hepatitis B Surface Antigen Test Strip, a significant advancement in the field of rapid Typhoid Ag detection. This product is an embodiment of years of our dedicated research and expertise in biotechnology. Utilizing lateral flow chromatographic immunoassay technology, the Hbsag Hepatitis B Surface Antigen Test Strip provides a quick and accurate method of identifying the Typhoid antigen present in feces. This innovative diagnostic tool gives you results in an efficient timeframe, thus enhancing the speed and effectiveness of subsequent treatment procedures. Our cutting-edge test strip is designed with the user's convenience in mind. Its simplicity of use empowers even those without specialist training to conduct tests, hence increasing accessibility to crucial early detection of Typhoid. Moreover, with its competency to provide precise results, it acts as a reliable tool in disease control, facilitating timely intervention and recovery.

PRINCIPLE

The Typhoid Ag Rapid Test Device (Feces) is a lateral flow chromatographic immunoassay. The test cassette consists of: 1) a burgundy colored conjugate pad containing S. typhoid antibody conjugated with colloid gold, 2) a nitrocellulose membrane strip containing two test bands (S.typhoid bands) and a control band (C band). The S. typhoid band is pre-coated with monoclonal anti- S. typhoid for the detection of S. typhoid Ag, and the C band is pre-coated with goat anti mouse IgG. When an adequate volume of test specimen is dispensed into the sample well of the cassette, the test specimen migrates by capillary action across the test cassette. S. typhoid Ag if present in the patient specimen will bind to the S. typhoid Ab conjugates. The immunocomplex is then captured on the membrane by the pre-coated S. typhoid antibody, forming a burgundy colored S. typhoid band, indicating a S. typhoid positive test result. Absence of any test bands suggests a negative result. The test contains an internal control (C band) which should exhibit a burgundy colored band of the immunocomplex of goat anti Mouse IgG/Mouse IgG-gold conjugate regardless of the color development on any of the test bands. Otherwise, the test result is invalid and the specimen must be retested with another device.


Product Detail

            • Brand: QL

              Specimens: : Faces

              Reading time:10 minutes.

              Pack:20 T

              STORAGE: 2‐30°C

              KIT COMPONENTS

              • Test devices
              • Droppers
              • Single Buffer
              • Package insert

 

  • ASSAY PROCEDURE

        • Bring tests, specimens, buffer and/or controls to room temperature (15-30°C) before use.

          1. Specimen collection and pre-treatment: 
          1) Unscrew and remove the dilution tube applicator. Be careful not to spill or spatter solution from the tube. Collect specimens by inserting the applicator stick into at least 3 different sites of the feces. 
          2) Place the applicator back into the tube and screw the cap tightly. Be careful not to break the tip of the dilution tube. 
          3) Shake the specimen collection tube vigorously to mix the specimen and the extraction buffer. Specimens prepared in the specimen collection tube may be stored for 6 months at -20°C if not tested within 1 hour after preparation. 
          2. Testing 
          1) Remove the test from its sealed pouch, and place it on a clean, level surface. Label the test with patient or control identification. To obtain a best result, the assay should be performed within one hour. 
          2) Using a piece of tissue paper, remove the tip of the dilution tube. Hold the tube vertically and dispense 3 drops of solution into the specimen well (S) of the test device. 
          Avoid trapping air bubbles in the specimen well (S), and do not drop any solution in observation window. 
          As the test begins to work, you will see color move across the membrane. 
          3. Wait for the colored band(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes.


        INTERPRETATION OF ASSAY RESULT

        • NOTE:

          • 1.The intensity of the color in test region (T) may vary depending on the concentration of aimed substances present in the specimen. Therefore, any shade of color in the test region should be considered positive. Besides, the substances level cannot be determined by this qualitative test.
          • 2.Insufficient specimen volume, incorrect operation procedure, or performing expired tests are the most likely reasons for control band failure.
          •  


        In addition to its ease of use and accuracy, the Hbsag Hepatitis B Surface Antigen Test Strip upholds the highest standards of safety. It has undergone rigorous testing and validation to ensure it provides consistently reliable results while reducing the risk of cross-contamination. By combining our commitment to quality with our drive for innovation, QL Biotech is trailblazing the path for rapid and precise diagnostic tools. The Hbsag Hepatitis B Surface Antigen Test Strip signifies our ongoing efforts to improve health outcomes through advanced technology. We continue to dedicate our energy and resources to contribute to a healthy tomorrow. Trust QL Biotech for accurate, swift, and safe Typhoid detection.