Quick Detection with Dengue NS1 Rapid Test Kit by QL Biotech
In today’s fast-paced world, the need for quick and accurate medical diagnostics is more crucial than ever, especially when it comes to diseases like malaria caused by Plasmodium falciparum. QL biotech is at the forefront of this battle, offering a groundbreaking solution with our Dengue NS1 Rapid Test Kit. This innovative product is designed to provide reliable results in just 10 minutes, making it an essential tool for both medical professionals and individuals seeking fast malaria detection.



The Dengue NS1 Rapid Test Kit is a testament to QL Biotech’s commitment to excellence and innovation in the field of biotechnology. Our kit is specifically designed for the detection of malaria Plasmodium falciparum, utilizing a rapid immuno-chromatographic assay to accurately identify the presence of the NS1 antigen in whole blood specimens. This method is not only highly efficient but also incredibly user-friendly, requiring no specialized equipment or training to perform. One of the key advantages of the Dengue NS1 Rapid Test Kit is its convenience and speed. With a reading time of just 10 minutes, it offers an unmatched fast turnaround for results, enabling timely decision-making in clinical and non-clinical settings. Whether it’s used in a hospital, clinic, or at home, our test kit ensures that individuals can quickly ascertain their malaria status and seek appropriate medical intervention if necessary. Our commitment to quality and reliability means that when you choose the Dengue NS1 Rapid Test Kit by QL Biotech, you are choosing a product that you can trust for accurate and rapid malaria detection.
Product Detail
-
Brand:QL
Specimens: : Whole Blood
Reading time:10 minutes.
Pack:25 T
STORAGE: 2‐30°C
KIT COMPONENTS
- Test devices
- Droppers
- Buffer
- Package insert
DIRECTIONS FOR USE
- Malaria Plasmodium Falciparum (P.f.) Rapid Test Device &
Malaria P.f./P.v. Rapid Test Device
Allow the test device, specimen, buffer, and/or controls to equilibrate to room temperature (15‐30°C)
prior to testing.
1. Remove the test device from the foil pouch and use it as soon as possible. Best results will be obtained if the assay is performed within one hour.
2. Place the test device on a clean and level surface. Transfer the specimen by a pipette or a dropper: To use a Pipette: Transfer 5 L of whole blood to specimen well of the test device, and then add 3 drops of buffer (approximately 180ul) to the buffer well, and start the timer.
To use a Disposable Specimen Dropper: Hold the dropper vertically; draw the specimen up to the Fill Line (approximately 5ul). Transfer the specimen to the specimen well, then add 3
drops of buffer (approximately 180ul) to the buffer well and start the timer. Wait for the colored line(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes. - Malaria Plasmodium Falciparum (P.f.) Rapid Test Strip
Allow the test strip, specimen, buffer, and/or controls to equilibrate to room temperature
(15‐30°C) prior to testing.
1. Remove the test strip from the foil pouch and use it as soon as possible. Best results will be obtained if the assay is performed within one hour.
2. Transfer the specimen to the specimen tube by a pipette or a dropper:
To use a Pipette: Transfer 10 L of whole blood to the specimen tube, then add 3 full drops of buffer (approximately 120L).
To use a Disposable Specimen Dropper: Hold the dropper vertically, draw the specimen up to the Fill Line as shown in illustration below (approximately 10L). Transfer the specimen to the specimen tube, then add 3 full drops of buffer (approximately 120L).
3. With arrows pointing toward the specimen, immerse the test strip vertically in the specimen and start the timer. Do not pass the maximum line (MAX) on the test strip when immersing the
strip.
4. Wait for the colored line(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes. - Malaria Pf/Pan Rapid Test Device
Allow the test device, specimen, buffer, and/or controls to equilibrate to room temperature (15‐30°C) prior to testing.
1. Remove the test device from the foil pouch and use it as soon as possible. Best results will be obtained if the assay is performed within one hour.
2. Place the test device on a clean and level surface. Transfer the specimen by a pipette or a dropper:
To use a Pipette: Transfer 5 L of whole blood to specimen well of the test device, and then add 3 drops of buffer (approximately 180ul) to the buffer well, and start the timer.
To use a Disposable Specimen Dropper: Hold the dropper vertically; draw the specimen up to the Fill Line (approximately 5ul). Transfer the specimen to the specimen well, then add 3 drops of buffer (approximately 180ul) to the buffer well and start the timer.
3. Wait for the colored line(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes.
P.f.
pf /Pv
Pf/Pan



The Dengue NS1 Rapid Test Kit is a testament to QL Biotech’s commitment to excellence and innovation in the field of biotechnology. Our kit is specifically designed for the detection of malaria Plasmodium falciparum, utilizing a rapid immuno-chromatographic assay to accurately identify the presence of the NS1 antigen in whole blood specimens. This method is not only highly efficient but also incredibly user-friendly, requiring no specialized equipment or training to perform. One of the key advantages of the Dengue NS1 Rapid Test Kit is its convenience and speed. With a reading time of just 10 minutes, it offers an unmatched fast turnaround for results, enabling timely decision-making in clinical and non-clinical settings. Whether it’s used in a hospital, clinic, or at home, our test kit ensures that individuals can quickly ascertain their malaria status and seek appropriate medical intervention if necessary. Our commitment to quality and reliability means that when you choose the Dengue NS1 Rapid Test Kit by QL Biotech, you are choosing a product that you can trust for accurate and rapid malaria detection.