Rapid Detection of Canine Distemper Virus and Influenza Virus Antigen - Troponin I Test Device
QL Biotech proudly introduces the Troponin I Rapid Test Device, a state-of-the-art diagnostic tool specifically designed for the detection of canine distemper virus and influenza virus antigen. This highly efficient product is user-friendly, providing accurate and rapid results for early detection of these viruses in whole blood, serum or plasma specimens.
Before using the Troponin I Rapid Test Device, ensure all components including the test device, specimen, buffer, and controls are at room temperature, preferably within the range of 15‐30°C. This temperature control is vital for the proper functioning of the product and delivery of reliable results.
Our rapid test device is an indispensable diagnostic tool for the timely detection of canine distemper virus and influenza virus antigen, playing a critical role in veterinary medicine by assisting in effective disease management. The Troponin I Rapid Test Device stands out with its superior accuracy, providing professionals with the certainty they need to make informed decisions about treatment.
POSITIVE RESULT:
A colored band appears in the control band region (C) and another colored band appears in the T band region.
NEGATIVE RESULT:
One colored band appears in the control band region (C). No band appears in the test band region (T).
INVALID RESULT:
Control band fails to appear. Results from any test which has not produced a control band at the specified reading time must be discarded. Please review the procedure and repeat with a new test. If the problem persists, discontinue using the kit immediately and contact your local distributor.
*NOTE: The intensity of the color in the test line region (T) will vary depending on the concentration of cTnI present in the specimen. Therefore, any shade of color in the test line region
(T) should be considered positive.
At QL Biotech, we are committed to delivering products that meet the highest standards of quality and efficiency. With the Troponin I Rapid Test Device, we've embodied this commitment, offering a product that enriches the field of canine medical diagnostics with its speed, reliability, and ease of use. By enabling rapid detection of the canine distemper virus and influenza virus antigen, we contribute to the overall wellbeing of dogs and other susceptible animals, ensuring they receive appropriate treatment as soon as possible. To ensure the continued effectiveness of the Troponin I Rapid Test Device, we encourage proper storage and handling. By following the provided instructions diligently, you can make the most of this innovative product, reaffirming our shared goal of prioritizing animal health. Trust QL Biotech for reliable, cutting-edge solutions for the detection of various canine diseases.
DIRECTIONS FOR USE
- Allow test device, specimen, buffer and/or controls to reach room temperature (15‐30°C) prior to testing.
1.Bring the pouch to room temperature before opening it. Remove the test device from the sealed pouch and use it as soon as possible.
2.Place the test device on a clean and level surface.
For Whole Blood, Serum or Plasma specimens:
Hold the dropper vertically and transfer 2 drops of specimen (or approximately 50 µL) to the specimen well (S) of the test device, then add 1 drop of buffer and start the timer.
For Fingerstick Whole Blood specimens:
To use a capillary tube: Fill the capillary tube and transfer approximately 50 µL (or 2 drops) of fingerstick whole blood specimen to the specimen well (S) of the test device, then add 1 drop of buffer and start the timer.
3.Wait for the colored line(s) to appear. Read results at 10 minutes. Do not interpret results after 20 minutes.
INTERPRETATION OF RESULTS
A colored band appears in the control band region (C) and another colored band appears in the T band region.
NEGATIVE RESULT:
One colored band appears in the control band region (C). No band appears in the test band region (T).
INVALID RESULT:
Control band fails to appear. Results from any test which has not produced a control band at the specified reading time must be discarded. Please review the procedure and repeat with a new test. If the problem persists, discontinue using the kit immediately and contact your local distributor.
*NOTE: The intensity of the color in the test line region (T) will vary depending on the concentration of cTnI present in the specimen. Therefore, any shade of color in the test line region
(T) should be considered positive.
At QL Biotech, we are committed to delivering products that meet the highest standards of quality and efficiency. With the Troponin I Rapid Test Device, we've embodied this commitment, offering a product that enriches the field of canine medical diagnostics with its speed, reliability, and ease of use. By enabling rapid detection of the canine distemper virus and influenza virus antigen, we contribute to the overall wellbeing of dogs and other susceptible animals, ensuring they receive appropriate treatment as soon as possible. To ensure the continued effectiveness of the Troponin I Rapid Test Device, we encourage proper storage and handling. By following the provided instructions diligently, you can make the most of this innovative product, reaffirming our shared goal of prioritizing animal health. Trust QL Biotech for reliable, cutting-edge solutions for the detection of various canine diseases.