Reliable M.Pneumoniae IgG/IgM Test Cassette - Strep A Rapid Test Kit by QL Biotech

Short Description:

The Strep A Rapid Test Device/Strip is a rapid chromatographic immunoassay for the qualitative detection of Strep A antigen from throat swab specimens to aid in the diagnosis of Group A Streptococcal infection.


Product Detail

Product Tags

Step into the future of quick and reliable testing with QL Biotech's Strep A Rapid Test Device, re-envisioned as the M.Pneumoniae IgG/IgM Test Cassette. This lateral flow immunoassay is qualitatively designed to provide swift detection of the Strep A carbohydrate antigen using a simple throat swab. The upgraded M.Pneumoniae IgG/IgM Test Cassette offers understanding and control at your fingertips. Its foundation lies in the novel concept of using lateral flow immunoassay technology, creating an accurate and efficient testing experience. This technology is designed for detecting and quantifying proteins and other biomolecular entities in complex mixtures. The test cassette's primary purpose lies in determining the presence of Strep A carbohydrate antigen promptly and efficiently. By incorporating the M.Pneumoniae IgG/IgM Test Cassette into your diagnostic toolkit, you'll gain valuable insights into the patient's health status, empowering you to make informed treatment decisions in a timely fashion. Apart from being fast and reliable, this testing device ensures utmost convenience. Simplicity is at the forefront of the design. Just a single throat swab is needed to initiate the process. This non-invasive method ensures minimal discomfort to the patient, encouraging cooperative behavior during medical procedures.

PRINCIPLE

The Strep A Rapid Test Device/strip is a qualitative, lateral flow immunoassay for the detection of Strep A carbohydrate antigen in a throat swab. In this test, antibody specific to Strep A carbohydrate antigen is coated on the test line region of the test. During testing, the extracted throat swab specimen reacts with an antibody to Strep A that is coated onto particles. The mixture migrates up the membrane to react with the antibody to Strep A on the membrane and generate a color line in the test line region. The presence of this color line in the test line region indicates a positive result, while its absence indicates a negative result. To serve as a procedural control, a colored line will always appear in the control line region, indicating that proper volume of specimen has been added and membrane wicking has occurred.


Product Detail

    • Brand:QL

      Specimens: : Swab

      Reading time:5 minutes.

      Pack:20 T

      STORAGE: 2‐30°C

      KIT COMPONENTS(Device)

      •  •Test devices                            •Sterile swabs
      •  •Workstation                         • Strep A Reagent A (1M Sodium Nitrite )
      •  •Strep A Reagent B (0.4M Acetic Acid)      • Test tubes
      •  •Dropper tips                          • Package insert

       

      KIT COMPONENTS(strip)

      •  •Test strips                           • Sterile swabs
      •  •Workstation                          • Strep A Reagent A (1M Sodium Nitrite )
      •  •Strep A Reagent B (0.4M Acetic Acid)   • Test tubes
      •  •Package insert

 

PROCEDURE

    • Allow the test device, reagents, throat swab specimen, and/or controls to reach room temperature (15-30°C) prior to testing. 
      1. Remove the test device from the sealed foil pouch and use it as soon as possible. 
      Best results will be obtained if the test is performed immediately after opening the foil pouch. 
      2. Hold the Reagent A bottle vertically and add 4 full drops (approximately 240 µL) of Reagent A to an extraction test tube. Reagent A is red in color. Hold the 
      Reagent B bottle vertically and add 4 full drops (approximately 160 µL) to the tube. Reagent B is colorless. Mix the solution by gently swirling the extraction test tube. The addition of Reagent B to Reagent A changes the color of the solution from red to yellow. 
      3. Immediately add the throat swab to the extraction test tube of yellow solution. Agitate the swab 10 times in the tube. Leave the swab in the tube for 1 minute. Then press the swab against the side of the tube and squeeze the bottom of the tube as the swab is withdrawn. Discard the swab. 
      4. Fit the dropper tip on top of the extraction test tube. Place the test device on a clean and level surface. Add 3 full drops of solution (approx. 100 µL) to the specimen well (S) and then start the timer. 
      5. Wait for the colored line(s) to appear. Read the result at 5 minutes. Do not read the result after 10 minutes.

    INTERPRETATION OF RESULTS


    • NOTE:
    • The intensity of the color in test region (T) may vary depending on the concentration of aimed substances present in the specimen. Therefore, any shade of color in the test region should be considered positive. Besides, the substances level can not be determined by this qualitative test.
    • Insufficient specimen volume, incorrect operation procedure, or performing expired tests are the most likely reasons for control band failure.

     



    In an increasingly health-conscious world, QL Biotech strives to stay at the forefront of medical innovation. Our M.Pneumoniae IgG/IgM Test Cassette is a testament to our ongoing dedication to providing reliable, effective, and user-friendly solutions. When it comes to your healthcare needs, we prioritize precision, speed, and simplicity. Explore the M.Pneumoniae IgG/IgM Test Cassette – an innovative breakthrough in rapid testing technology. By choosing QL Biotech, you choose accuracy, efficiency, and a trustworthy healthcare companion.