Revolutionary Fob Rapid Test Kit: Ferritin Detection Simplified

Short Description:

The Human Ferritin Rapid Test Device (Whole blood/Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of human Ferritin in human whole blood, serum and

plasma.


Product Detail

Product Tags

The Fob Rapid Test Kit is a radical leap in our innovative line of diagnostic tools. It is an avant-garde, lateral flow immunoassay that delivers qualitative results in Ferritin detection in human whole blood, serum, and plasma. Designed to revolutionize traditional testing methods, this cutting-edge kit is tailored for the effective detection of human Ferritin levels. The Fob Rapid Test Kit operates on a robust and dynamic principle. It leverages the lateral flow immunoassay methodology, a reliable and proven technique known for its accuracy and efficient results in conducting bioanalysis. With this advanced method, the kit provides precise, quick, and uncomplicated Ferritin detection solutions to facilitate quicker medical interventions. The unique feature of our Fob Rapid Test Kit is its versatility in sample handling. Whether you're dealing with whole blood, serum, or plasma, this kit produces consistent and reliable results. No longer do you need separate tools for each sample, as this kit meets all your Ferritin detection needs in one place.

PRINCIPLE

The Human Ferritin Rapid Test Device (Whole blood/Serum/Plasma) is a qualitative, lateral flow immunoassay for the detection of human Ferritin in human whole blood, serum and plasma. The membrane is pre‐coated with anti‐ferritin antibody on the test line region of the strip. During testing, the specimen reacts with the particle coated with anti‐ferritin antibody. The mixture

migrates upward on the membrane chromatographically by capillary action to react with anti‐ferritin antibody on the membrane and generate a colored line. The presence of this colored

line in the test region indicates a positive result, while its absence indicates a negative result. To serve as a procedural control, a colored line will always appear in the control line region

indicating that the proper volume of specimen has been added and membrane wicking has occurred.

 

PRECAUTIONS

For professional in vitro diagnostic use only. Do not use after expiration date.

  • ● The test device should remain in the sealed pouch until use.
  • ● Do not eat, drink or smoke in the area where the specimens or kits are handled.
  • ● Do not use if pouch is damaged.
  • ● Handle all specimens as if they contain infectious agents. Observe established precautionsagainst microbiological hazards throughout the procedure and follow the standard proceduresfor proper disposal of specimens.
  • ● Wear protective clothing such as laboratory coats, disposable gloves or eye protection whenspecimens are being tested.
  • ● Humidity and temperature can adversely affect results.

DIRECTIONS FOR USE

Allow test device, specimen, buffer and/or controls to reach room temperature (15‐30°C)  prior to testing. 
1. Bring the pouch to room temperature before opening it. Remove the test device from the sealed pouch and use it as soon as possible. 
2. Place the test device on a clean and level surface. 
For Whole Blood, Serum or Plasma specimens: 
Hold the dropper vertically and transfer 2 drops of specimen (or approximately 50 µL) to the specimen well (S) of the test device, then add 1 drop of buffer and start the timer. 
For Fingerstick Whole Blood specimens: 
To use a capillary tube: Fill the capillary tube and transfer approximately 50 µL (or 2 drops) of fingerstick whole blood specimen to the specimen well (S) of the test device, then add 1 drop of buffer and start the timer. 
3. Wait for the colored line(s) to appear. Read results at 10 minutes. Do not interpret results after 20 minutes. 

PERFORMANCE CHARACTERISTICS

Accuracy

The Transferrin Rapid Test Device (Feces) has been compared with another leading commercial rapid test using clinical specimens.

Method

Other Rapid Test

 

Total Results

 

TF Rapid Test Device

 

Results

Positive

Negative

Positive

20

0

20

Negative

0

20

20

Total Results

20

20

20

Relative Sensitivity: >99.9 %

Relative Specificity: >99.9 %

Relative Accuracy: >99.9 %

Sensitivity

The Human Ferritin Rapid Test Device (Whole blood/Serum/Plasma) can detect the levels of human ferritin as low as 20 ng/mL ferritin.

Interfering Substances

The Human Ferritin Rapid Test Device (Whole blood/Serum/Plasma) has been tested and no interference was observed in specimens containing 110mg/mL human albumin, 6 mg/mL bilirubin, 5 mg/mL cholesterol and 15 mg/mL triglycerides.




Moreover, the convenience offered by the Fob Rapid Test Kit is unparalleled. It eliminates the need for exhaustive lab procedures, making it a reliable choice for Ferritin detection in urgent cases. With the Fob Rapid Test Kit, quick detection can now pave the way to a more timely treatment plan. In conclusion, the Fob Rapid Test Kit encapsulates QL Biotech's mission to simplify diagnostic procedures without compromising accuracy and efficiency. The perfect blend of innovation, versatility, and speed in Ferritin detection, this kit is set to become an indispensable tool in the healthcare landscape. Trust the Fob Rapid Test Kit, and experience the future of swift and precise Ferritin detection today.