Swift Diagnosis with Typhoid Rapid Test Cassette - QL Biotech

Short Description:

The Typhoid Ag Rapid Test Device (Feces) is a lateral flow immunoassay for the simultaneous detection and differentiation of Salmonella Typhoid in feces.


Product Detail

Product Tags

Experience precision, efficiency, and swift results with QL Biotech's Typhoid Rapid Test Cassette. Our innovative technology, embedded in a lateral flow chromatographic immunoassay, makes the diagnosis of Typhoid as seamless as possible. The Typhoid Rapid Test Cassette serves as a critical tool in the detection and diagnosis of Typhoid, an illness that can have severe implications if not diagnosed early and accurately. Our cassette is specifically designed to offer an instant and reliable test result, giving healthcare professionals immediate access to vital information that can drastically enhance the speed and effectiveness of the treatment process. The Typhoid Rapid Test Cassette operates on the principle of lateral flow chromatographic immunoassay, an advanced technique that is designed to deliver high precision test results. The methodology behind this technology allows for quick detection of the presence of antigens associated with typhoid in feces samples. In practice, the Typhoid Rapid Test Cassette offers a swift course of action for the early detection and management of typhoid. It carries the advantage of speed, combined with impressive accuracy; two attributes that are essential in the field of health diagnosis. This compact device ensures that diagnostic results are available in a quick and hassle-free manner.

PRINCIPLE

The Typhoid Ag Rapid Test Device (Feces) is a lateral flow chromatographic immunoassay. The test cassette consists of: 1) a burgundy colored conjugate pad containing S. typhoid antibody conjugated with colloid gold, 2) a nitrocellulose membrane strip containing two test bands (S.typhoid bands) and a control band (C band). The S. typhoid band is pre-coated with monoclonal anti- S. typhoid for the detection of S. typhoid Ag, and the C band is pre-coated with goat anti mouse IgG. When an adequate volume of test specimen is dispensed into the sample well of the cassette, the test specimen migrates by capillary action across the test cassette. S. typhoid Ag if present in the patient specimen will bind to the S. typhoid Ab conjugates. The immunocomplex is then captured on the membrane by the pre-coated S. typhoid antibody, forming a burgundy colored S. typhoid band, indicating a S. typhoid positive test result. Absence of any test bands suggests a negative result. The test contains an internal control (C band) which should exhibit a burgundy colored band of the immunocomplex of goat anti Mouse IgG/Mouse IgG-gold conjugate regardless of the color development on any of the test bands. Otherwise, the test result is invalid and the specimen must be retested with another device.


Product Detail

            • Brand: QL

              Specimens: : Faces

              Reading time:10 minutes.

              Pack:20 T

              STORAGE: 2‐30°C

              KIT COMPONENTS

              • Test devices
              • Droppers
              • Single Buffer
              • Package insert

 

  • ASSAY PROCEDURE

        • Bring tests, specimens, buffer and/or controls to room temperature (15-30°C) before use.

          1. Specimen collection and pre-treatment: 
          1) Unscrew and remove the dilution tube applicator. Be careful not to spill or spatter solution from the tube. Collect specimens by inserting the applicator stick into at least 3 different sites of the feces. 
          2) Place the applicator back into the tube and screw the cap tightly. Be careful not to break the tip of the dilution tube. 
          3) Shake the specimen collection tube vigorously to mix the specimen and the extraction buffer. Specimens prepared in the specimen collection tube may be stored for 6 months at -20°C if not tested within 1 hour after preparation. 
          2. Testing 
          1) Remove the test from its sealed pouch, and place it on a clean, level surface. Label the test with patient or control identification. To obtain a best result, the assay should be performed within one hour. 
          2) Using a piece of tissue paper, remove the tip of the dilution tube. Hold the tube vertically and dispense 3 drops of solution into the specimen well (S) of the test device. 
          Avoid trapping air bubbles in the specimen well (S), and do not drop any solution in observation window. 
          As the test begins to work, you will see color move across the membrane. 
          3. Wait for the colored band(s) to appear. The result should be read at 10 minutes. Do not interpret the result after 20 minutes.


        INTERPRETATION OF ASSAY RESULT

        • NOTE:

          • 1.The intensity of the color in test region (T) may vary depending on the concentration of aimed substances present in the specimen. Therefore, any shade of color in the test region should be considered positive. Besides, the substances level cannot be determined by this qualitative test.
          • 2.Insufficient specimen volume, incorrect operation procedure, or performing expired tests are the most likely reasons for control band failure.
          •  


        Our goal at QL Biotech is to uphold rigorous standards of quality, efficiency, and reliability in all our products. The Typhoid Rapid Test Cassette reflects this commitment to the best standards in the field of medical diagnostics. Armed with our Typhoid Rapid Test Cassette, healthcare professionals can provide prompt and accurate diagnosis, ultimately leading to more effective treatment plans, and better patient outcomes. In conclusion, the Typhoid Rapid Test Cassette from QL Biotech stands as a symbol of our innovation and dedication towards streamlined, swift, and precise health diagnostics. Trust in our advanced lateral flow chromatographic immunoassay system to deliver exceptional results when you need them the most.

      • Previous: